Or. Admin. Code § 411-348-0280 - Fire Safety Requirements
(1) Each
Host Home must be fire safe, including the following standards:
(a) Each Host Home must have a minimum of two
exterior doorway exits allowing for egress.
(b) Sleeping and living quarters must have a
minimum of two unobstructed emergency escape and rescue openings.
(c) A working fire extinguisher in compliance
with state-adopted fire code that is easily accessible must be provided on each
floor of a Host Home.
(A) Fire extinguishers
must be checked on a monthly basis by the in-residence caregiver to ensure the
locking pin is intact, the tamper seal is unbroken, and the extinguisher has no
obvious signs of damage, corrosion, leakage, or clogs.
(B) Fire extinguishers must be inspected and
certified annually by a fire protection equipment company. A complete breakdown
and internal inspection must be done every six years by a fire protection
equipment company.
(d)
Permanent wired smoke alarms from a commercial source with a battery back-up
must be provided and maintained in each bedroom and at a point centrally
located on each floor in the corridor or area giving access to each separate
sleeping areas. A Host Home may be granted an exception according to section
(2) of this rule.
(e) A 13D
residential sprinkler system in accordance with the National Fire Protection
Association Code must be provided and maintained. A Host Home may be granted an
exception according to section (2) of this rule.
(f) Hardware for all exit doors and interior
doors must be simple hardware that may not be locked against exit and must have
an obvious method of operation. Hasp, sliding bolts, hooks and eyes, double key
deadbolts, and childproof doorknobs are not permitted. A deadbolt must be
single action release to allow a door to open in a single operation.
(2) A Host Home is granted an
exception to the requirements in sections (1)(d) and (e) of this rule under all
of the following circumstances:
(a) All
children receiving services in the Host Home have demonstrated the ability to
respond to an emergency alarm with or without physical assistance from the
in-residence caregiver or staff to the exterior and away from the Host Home in
three minutes or less, as evidenced by three or more consecutive documented
fire drills.
(b) Battery operated
smoke alarms with a 10-year battery life and hush feature have been installed
in accordance with the manufacturer's listing, in each bedroom, adjacent
hallways, common living areas, basements, and in two-story homes at the top of
each stairway. Ceiling placement of smoke alarms is recommended. If wall
mounted, smoke alarms must be mounted as per the manufacturer's instructions.
Alarms must be equipped with a device that warns of low battery condition when
battery operated. All smoke alarms must be maintained in functional
condition.
(c) A written fire
safety evacuation plan is implemented according to OAR
411-348-0260 that assures the
in-residence caregiver and staff assist all children in evacuating the premises
safely during an emergency or fire as documented by fire drill
records.