Or. Admin. Code § 437-002-0266 - Additional Oregon Rules for Guarding Portable Powered Tools
(1) Lower Guard. In
addition to the provisions in 1910. 243(a)(1)(i), the lower guard shall be
equipped with a lug or lever, remote from the blade teeth, that will permit the
operator to safely shift the guard for starting unusual cuts.
(2) Power Chain Saws:
(a) In addition to the provisions of
1910.243(a) (2)(i), all power chain saws shall meet all applicable requirements
of the ANSI B175.1-1985, Safety Code for Power Chain Saws;
(b) Power saws shall be inspected daily when
in use and kept in good repair at all times. Saws with cracked or loose handle
bars or defective vital parts shall not be used;
(c) Power chain saw engines shall be stopped
while being fueled;
(d) Power chain
saws shall have an operable chain brake if originally designed and equipped
with a chain brake;
(e) Chain
brakes, and other manufacturer's safety features shall remain operational at
all times.
(3)
Pneumatic-Powered Tools:
(a) A shut-off valve
shall be installed at the manifold or permanent pipe outlet of the compressed
air supply;
(b) Workers shall not
couple or uncouple hose without first shutting off the compressed air supply
except when using couplers which are equipped with check valves which
automatically shut off the compressed air supply;
(c) Workers shall remain in the clear when
turning on air supply at a valve;
(d) Driving pistons in pneumatic tools shall
be constructed so that they cannot fly out of the tool;
(e) Pneumatic fastener-driving tools and
other power-driven fastener tools, except as allowed in subsection (f) of this
section, shall be equipped with a safety device to prevent ejection of nails or
staples when the tool is not in firm contact with the work;
(f) Power-driven fastener-driving tools may
be used without the safety device only when using staples with a diameter of
.0475 inch (18 gauge A.W.G.) or less and the tool operator and all workers
within 15 feet are wearing suitable eye protection;
(g) The provisions of subsection (f) of this
section do not apply to office stapling machines;
(h) Oxygen or combustible gases shall not be
used to drive pneumatic tools;
(i)
The exhaust from pneumatic power tools shall be deflected away from the
operator.
(4) Internal
Combustion Engine-Driven Tools:
(a) Internal
combustion engine-driven tools shall be equipped with a positive on and off
ignition switch that will remain in either position;
(b) Internal combustion engine-driven tools
shall be equipped with effective means to control power except those which are
designed to operate at constant speed. Throttle controls shall return the
engine to idling speed when released;
(c) Internal combustion engine-driven tools
shall be equipped with a self-rewinding starting device, or be designed to
furnish equivalent safety;
(d)
Exhaust ports on internal combustion engine-driven tools shall be equipped with
mufflers and shall be constructed and maintained to deflect exhaust fumes away
from the operator when the tool is being used in its normal starting
position;
(e) Internal combustion
engine-driven tools shall be stopped while being fueled;
(f) Sling-carried tools which are powered by
attached portable internal combustion engines shall be capable of quick
removal;
(g) The fuel system of
sling-carried tools shall be inspected before each use, and any defect shall be
repaired immediately.
Notes
Stat. Auth.: ORS 654.025(2) & ORS 656.726(3)
Stats. Implemented: ORS 654.001 - ORS 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.