Or. Admin. Code § 437-002-0299 - Definitions
(1) Terms used in
Division 2/Q
(a) Approved: listed or approved
by a nationally recognized testing laboratory (NRTL). Note: 1910.7 has NRTL
requirements.
(b) Coated steels:
include metal coated to provide a protective covering such as to prevent
rusting or to shield the metal from chemicals. Protective coatings can contain
chromium, lead, tin, zinc or other potentially hazardous materials. During hot
work, the coatings can give off fumes, smoke, or dust. Welders must know what a
coating can give off when heated or burned. This information is available on
the manufacturers' Safety Data Sheets. Permissible Exposure Limits for these
materials must not be exceeded.
(c)
Competent person: a person capable of identifying existing and predictable
hazards in the work environment which are unsanitary, hazardous, or dangerous
to employees; and who has authorization to take prompt corrective measures to
eliminate these hazards.
(d)
Confined space: As defined in OAR
437-002-0146, a space that meets
all of the following:
(A) Large enough and so
configured that an employee can fully enter the space and perform
work.
(B) Has limited or restricted
means for entry or exit.
(C) Is not
designed for continuous human occupancy.
(e) Feasible: In this context, something that
is possible or capable of being done and that effectively accomplishes the goal
of protecting employees.
(f) Hot
work activities: include welding, torch-cutting, brazing and any similar
activity that produces heat or a source of ignition.
(g) Toxic substance or harmful physical
agent: As defined in 1910.1020, any chemical substance, biological agent
(bacteria, virus, fungus, etc.), or physical stress (noise, heat, cold,
vibration, repetitive motion, ionizing and non-ionizing radiation, hypo- or
hyperbaric pressure, etc.) which:
(A) Is
listed in the latest printed edition of the National Institute for Occupational
Safety and Health (NIOSH) Registry of Toxic Effects of Chemical Substances
(RTECS); or
(B) Has yielded positive
evidence of an acute or chronic health hazard in testing conducted by, or known
to, the employer; or
(C) Is the
subject of a safety data sheet kept by or known to the employer indicating that
the material may pose a hazard to human health.
(2) Welding, cutting or grinding tasks
reference in Table OR Q-2:
(a) Carbon Arcing -
or carbon gouging -- is an arc cutting process in which metals to be cut are
melted by the heat of the carbon arc and the molten metal is removed by a blast
of air.
(b) Flux-Cored Arc Welding
(FCAW) -- or FCA or MIG flux core welding -- is an automatic or semi-automatic
arc welding process requiring a continuously fed consumable tubular electrode
containing a flux. (Shielding gas is often not needed; but a constant welding
current or power supply is required.)
(c) Gas Metal Arc Welding (GMAW) - or MIG
Solid Wire uses a spooled, solid steel wire fed through a welding lead to the
welding gun.
(d) Gas Tungsten Arc
Welding (GTAW) -- or Tungsten Inert Gas -- TIG Welding (also called "Heliarc"
welding) uses a non-consumable tungsten electrode to produce the weld and an
inert gas to shield the weld from the atmosphere.
(e) Grinding tasks directly related to the
welding process include the preparation of metal surfaces such as the removal
of coatings, rust, or oxidation; and beveling or otherwise reducing the
thickness at the edge of the metal to be joined by welding.
(f) Hand-held means any welding or cutting
process where the torch or electrode holder is manipulated by hand.
(g) Torch cutting includes heating the metal
with a torch flame until it is red, then using a blast trigger to deliver a
higher concentration of oxygen that forces the molten metal away, creating a
cut.
(h) Plasma Cutting uses a
high-intensity plasma arc to melt a very narrow area that pushes through the
work piece and removes the molten metal.
(i) Shielded Metal Arc Welding (SMAW) - also
called "stick" welding -- uses a stick-type electrode core covered by chemical
or metallic materials that provide shielding from surrounding air to complete
an electrical circuit. Typically, a holder keeps the electrode at a chosen
angle.
(3) Notes about the
recommended "Standard order for atmospheric testing" in a confined or other
enclosed space:
(a) Before workers are allowed
to enter confined and enclosed spaces, and at sufficient intervals to ensure
safe conditions, a person competent in the use of atmospheric testing equipment
may be required to test the atmosphere.
(b) The following is considered the standard
order of testing and provides guidelines for ranges of concentration that are
recognized as safe:
(A) Oxygen. To support
life, Oxygen content levels must be maintained at or above 19.5% and below
22.0% by volume. (Above 22.0% by volume is an "oxygen-enriched atmosphere with
additional safety hazards for fire and explosion.) If an oxygen-deficient or
oxygen-enriched atmosphere is found, ventilation must be provided at volumes
and flow rates sufficient to restore oxygen content to the safe
range.
(B) Flammable gases/ vapors.
The concentration of flammable gasses or vapors must be maintained below 10% of
the Lower Explosive Limit (LEL).
(C)
Toxic vapors. The types of toxic gases, vapors, or fumes present will depend on
the types of materials being worked on and worked with. These air contaminants
must be maintained below the OSHA permissible exposure limits (PELs). If there
is no established OSHA PEL, the levels must be maintained below the NIOSH
immediately dangerous to life and health (IDLH) level. Local exhaust
ventilation can remove these contaminants at their source while general exhaust
ventilation -- provided at sufficient volumes and flow rates -- can restore
concentrations to safe levels.
Notes
Statutory/Other Authority: ORS 654.025(2), 654.035, 656.726(4)
Statutes/Other Implemented: ORS 654.001 through 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.