Or. Admin. Code § 437-002-0312 - Oregon Rules for Pulp, Paper and Paperboard Mills
(1) General Requirements.
(a) Application. This section applies to
establishments where pulp, paper, and paperboard are manufactured or converted.
This section does not apply to logging and the transportation of logs to pulp,
paper, and paperboard mills.
(b)
Standards incorporated by reference. Standards covering issues of occupational
safety and health which have general application without regard to any specific
industry are incorporated by reference in sections (2) through (14) of this
rule and in subsections (c) and (d) of this rule and made applicable under this
rule. Such standards shall be construed according to the rules set forth in
§1910.5, Applicability of Standards, in Subdivision A.
(c) General incorporation of standards.
Establishments subject to this section shall comply with the following
standards of the American National Standards Institute:
(A) Safety Requirements for Floor and Wall
Openings, Railings, and Toeboards, A10.18-1983.
(B) Scheme for the Identification of Piping
Systems, A13.1-1981 (R1993).
(C)
Safety Code for Portable Wood Ladders, A14.1-1990.
(D) Safety Code for Portable Metal Ladders,
A14.2-1990.
(E) Safety Code for
Fixed Ladders, A14.3-1990.
(F)
Safety Code for Cranes, Derricks, and Hoists, B30.2-1990.
(G) Overhead and Gantry Cranes, B30.17-1992.
(H) Crawler, Locomotive, and Truck
Cranes, B30.8-1993.
(I) Safety
Code for Woodworking Machinery, ANSI O1.1-1992.
(J) Method of Measurement of Real-Ear
Protection of Hearing Protectors - Physical Attenuation of Ear Muffs, ANSI
S3.19-1974 (R1990).
(K) Practice
for Occupational and Educational Eye and Face Protection, ANSI Z87.1-1989.
(L) Requirements for Sanitation in
Places of Employment, ANSI Z4.1-1986.
(M) Fundamentals Governing the Design and
Operation of Local Exhaust Systems, Z9.2-1979 (R 1991).
(N) Practices for Respiratory Protection,
ANSI Z88.2-1992.
(O) Safety
Requirements for Industrial Head Protection, ANSI Z89.1-1986.
(P) Safety Color Code, ANSI Z535.1-1991.
(Q) Practice for the Inspection of
Elevators (Inspector's Manual), ANSI/ASME A17.2-1988.
(R) Safety Code for Elevators, Dumbwaiters,
and Moving Walks, ANSI/ASME A17.1-1990.
(S) Safety Code for Mechanical
Power-Transmission Apparatus, ANSI/ASME B15.1-1992.
(T) Safety Code for Conveyors, Cableways, and
Related Equipment, ANSI/ASME B20.1-1993.
(U) Power Piping, ANSI/ASME B31.1-1992.
(V) Safety Code for Powered
Industrial Trucks, ANSI/ASME B56.1.
(W) Practice for Industrial Lighting,
ANSI/IES RP-990.
(X) Installation
of Blower and Exhaust Systems for Dust, Stock, and Vapor Removal or Conveying,
ANSI/NFPA 91-1992.
(Y) Fire
Department Self-Contained Breathing Apparatus Program, ANSI/NFPA 1404-1989.
(Z) Safety Code for Ventilation
and Operation of Open-Surface Tanks, ANSI/UL 641-1985.
(d) Other standards. The following standards
shall be considered standards under this section:
(A) ASME Boiler and Pressure Vessel Code,
Section VIII, Unfired Pressure Vessels 1992, including addenda.
(B) Building Exits Code for Life Safety from
Fire, NFPA 101-1991.
(C) NFPA Code
for Prevention of Sulfur Fires and Explosions, NFPA 655-1993.
(D) Safety in the Transportation, Storage,
Handling and Use of Explosives, IME Pamphlet No. 17, March 1987, Institute of
Makers of Explosives.
(2) Employee Training.
(a) Employees shall not be permitted to
operate any machine or equipment until they have received proper training and
are familiar with safe operating procedures.
(b) Employees shall be trained in proper
lifting or moving techniques and methods. Mechanical devices should be used or
employees should ask for assistance in lifting or moving heavy objects.
(c) In each area where hazardous
substances may be encountered, personnel shall be trained to cope with
emergencies arising from breaks, ruptures, or spills which would create a
hazardous condition.
(d) Any
faulty equipment or hazardous condition shall be promptly reported to the
person in charge.
(e) When an
employee is assigned to work alone in a remote or isolated area, a system shall
be instituted whereby such employee reports to someone or a designated person
shall check on his or her safety. The procedure shall designate the method of
contact and the frequency. All persons will be trained on the procedures.
(3) Safe Practices.
(a) Guards. All driving mechanisms, power
transmission apparatus, and prime movers shall be constructed, guarded, and
used in conformity with Subdivision O, Machinery and Machine Guarding.
(b) Inspection of controls and
safety devices. Brakes, back stops, antirunaway devices, overload releases, and
other safety devices shall be inspected and tested frequently to insure that
all are operative and maintained in good repair.
(c) Personal protective clothing and
equipment. Personal protective clothing and equipment shall be provided and
worn in accordance with Subdivision I, Personal Protective Equipment.
Respiratory protection must conform to the requirements of §1910.134 of
Subdivision I.
(d) Floors and
platforms. Floors, platforms, and work surfaces shall be guarded and maintained
in accordance with Subdivision D, Walking-Working Surfaces.
(e) Lockouts. Lockout/tagout shall be in
accordance with the requirements of §1910.147, in Subdivision J, with the
exception that:
(A) There will be no tagouts
allowed in lieu of lockout for that which can be locked out. Tags are provided
for identification and information purposes only.
(B) Persons engaged in repair, inspection,
maintenance, or clean-up shall lockout the affected equipment, retain
possession of the keys to the locks, and personally remove the lock and tag
upon completion of the work.
(C)
Group lockout. (See Appendices A and B.)
(i)
When servicing and/or maintenance is performed by a crew, craft, department or
other group, they shall utilize a procedure which affords the employees a level
of protection equivalent to that provided by the implementation of a personal
lockout device.
(ii) Group lockout
devices shall be used in accordance with the procedures required by
§1910.147(c)(4) including, but not necessarily limited to, the following
specific requirements.
(I) Primary
responsibility is vested in an authorized employee for a set number of
employees working under the protection of a group lockout device (such as an
operations lock);
(II) Provision
for the authorized employee to ascertain the exposure status of individual
group members with regard to the lockout of the machine or equipment; and
(III) When more than one crew,
craft, department, etc. is involved, assignment or overall job-associated
lockout control responsibility to an authorized employee designated to
coordinate affected work forces and ensure continuity of protection; and
(IV) Each authorized employee
shall affix a personal lockout device to the group lockout device, group
lockbox, or comparable mechanism when he or she begins work, and shall remove
those devices when he or she stops working on the machine or equipment being
serviced or maintained; and
(V)
Any person involved in the lockout process shall have the right to place their
own lock at each lockout location where group lockout procedures have been
allowed.
(f) Confined space entry. Confined space
entry shall be in accordance with
437-002-0146 Confined Spaces, in
Subdivision J.
(g) Industrial
power trucks.
(A) All industrial power trucks
and operations shall conform to §1910.178, Powered Industrial Trucks,
Subdivision N, Material Handling and Storage. All forklift trucks shall be
provided with overhead guards. Design requirements shall provide protection for
the liquid petroleum gas tank. All guards shall be designed in compliance with
§1910.178, Powered Industrial Trucks, in Subdivision N.
(B) Mirrors or other methods to ensure
visibility shall be installed at blind corners or intersections which will
allow operators to observe oncoming traffic.
(C) Every power truck operated from an end
platform or standing position shall be equipped with a platform extending
beyond the operator's position, strong enough to withstand a compression load
equal to the weight of the loaded vehicle applied along the longitudinal axis
of the truck with the outermost projection of the platform against the flat
vertical surface.
(D) Pushing of
vehicles or rail cars with the forks or clamps of a lift truck is prohibited.
(h) Emergency lighting.
(A) Emergency lighting shall be provided
wherever it is necessary for employees to remain at their machines or stations
to shut down equipment in case of power failure. Emergency lighting shall be
provided at stairways and passageways or aisleways used by employees for
emergency exit in case of power failure. Emergency lighting shall be provided
in all plant first aid and medical facilities.
(B) Emergency lighting shall be maintained in
accordance with the manufacturer or engineering specifications, and shall be
checked at least every 30 days for defects.
(i) Electrical equipment. All electrical
installations and electrical utilization equipment shall comply with the
National Electrical Code requirements and the provisions of Subdivision S,
Electrical.
(4)
Handling and Storage of Pulpwood and Pulp Chips.
(a) Handling pulpwood with forklift trucks.
Where large forklift trucks, or lift trucks with clam-jaws, are used in the
yard, the operator's enclosed cab shall be provided with an escape hatch,
whenever the hydraulic arm blocks escape through the side doors.
(b) Handling pulpwood with cranes or
stackers.
(A) Where locomotive cranes are
used for loading or unloading pulpwood, the pulpwood shall be piled so as to
allow a clearance of not less than 24 inches between the pile and the end of
the cab of any locomotive crane in use, when the cab is turned in any working
position.
(B) The minimum distance
of the pulpwood pile from the centerline of a standard-gage track shall be
maintained at not less than 8-1/2 feet.
(C) Logs shall be piled in an orderly and
stable manner, with no projection into walkways or roadways.
(D) Rail cars shall not be spotted on tracks
adjacent to the locomotive cranes unless a 24 inch clearance is maintained, as
required in section (4)(b)(A) of this rule.
(E) The handling and storage of other
materials shall conform to sections (4)(b)(A) and (B) of this rule with respect
to clearance.
(F) Equipment and
practices shall conform to American National Standards B30.2-1990 and
B30.2.0-1967.
(G) Personal
protective equipment for such uses as foot, head, and eye protection shall be
required for workers on a job basis.
(H) No person shall be permitted to walk
beneath a suspended load, bucket, or hook.
(c) Pulpwood storage and handling.
(A) Unauthorized vehicles and unauthorized
foot traffic shall not be allowed in any active sorting, storing, loading, or
unloading areas.
(B) Unloading
lines shall be so arranged that it is not necessary for the workers to attach
them on the pond or dump side of the load.
(C) Jackets or vests of fluorescent or other
high visibility material shall be worn by persons working on dry land log
storage.
(D) Wire rope doglines
used for towing or rafting shall not be used when:
(i) They acquire jaggers to the extent that
they present a hazard to the workers handling them; or
(ii) When they are weakened to the extent
that they are hazardous.
(E) Boom sticks shall be capable of safely
supporting the weight imposed upon them.
(F) Stiff booms shall be made by fastening
not less than two boom sticks together. The width of the stiff boom shall be
not less than 36 inches measured from outside to outside of the outer logs. The
boom sticks shall be fastened together with not less than 4-inch by 6-inch
cross ties or cable lashing properly recessed into notches in the boom sticks
and secured.
(G) Pike poles shall
be kept in good repair. Conductive pike poles shall not be used where it is
possible that they may come in contact with electrical conductors.
(H) All log dumps shall be periodically
cleared of bark and other debris.
(I) When cutting bands on bundled logs,
workers shall position themselves in a safe location. Double-bitted axes shall
not be used for cutting bands. Caution shall be used to prevent being struck by
ends of bands being cut and, if needed, personal protective equipment shall be
worn.
(J) Storing or sorting on
water, or any boom work other than boom boat operations, shall require a
minimum of two persons.
(d) Handling pulpwood from ships.
(A) Ladders and gangplanks with railings to
boat docks shall meet the requirements of American National Standards
A10.18-1983, A14.1-1990, A14.2-1990, and A14.3-1990, and shall be securely
fastened in place.
(B) The hatch
tender shall be required to signal the hoisting engineer to move the load only
after the employees working in the hold are in the clear.
(C) The air in the ship's hold, tanks, or
closed vessels shall be tested for oxygen deficiency and for toxic, explosive
and combustible gases and vapors.
(e) Handling pulpwood from flatcars and all
other rail cars.
(A) Railroad flatcars for
the conveyance of pulpwood loaded parallel to the length of the car shall be
equipped with safety-stake pockets.
(B) Where pulpwood is loaded crosswise on a
flatcar sufficient stakes of sizes not smaller than 4 by 4 inches shall be used
to prevent the load from shifting.
(C) When it is necessary to cut stakes, those
on the unloading side should be partially cut through first, and then the
binder wires cut on the opposite side. Wire cutters equipped with long
extension handles shall be used. No person shall be permitted along the dumping
side of the car after the stakes have been cut.
(D) When steel straps without stakes are
used, the steel straps shall be cut from a safe area to prevent employees from
being struck by the falling logs.
(E) Flatcars and all other cars shall be
chocked during unloading. Where equipment is not provided with hand brakes,
rail clamping chocks shall be used.
(F) A derail shall be used to prevent
movement of other rail equipment into cars where persons are working.
(f) Handling pulpwood
from trucks.
(A) Cutting of stakes and binder
wires shall be done in accordance with section (4)(e)(C) of this rule.
(B) Where binder chain and steel
stakes are used, the binder chains shall be released and the stakes tripped
from the opposite side of the load spillage.
(C) Where binder chains and crane slings are
used, the crane slings shall be attached and taut before the binder chains are
released. The hooker shall see that the helper is clear before signaling for
the movement of the load.
(D) The
truck driver shall leave the truck cab and be in the clear, in a designated
area, and shall be in clear view of the unloading equipment operator while the
unloader is approaching the loaded truck.
(E) The truck driver shall remain outside the
cab and clear of the load while logs are being unloaded except that, after a
complete load is lifted as a unit and held stationary, the driver may enter the
cab and drive forward from under the suspended load.
(F) Log unloaders shall not be moved about
the premises with loads raised higher than absolutely necessary.
(g) Handling pulp chips from rail
cars.
(A) All cars shall be securely fastened
in place and all employees in the clear before dumping is started.
(B) Personal protective equipment for such
uses as foot, head, and eye protection shall be provided, and employees shall
wear the equipment when working in the woodyard. Ear protection shall be
provided when the noise level may be harmful.
(C) When a rollover-type unloading device is
used for removing chips from cars, the cars shall be properly secured in place,
and all employees shall be in the clear before dumping operation is started.
(h) Handling pulp chips
and hog fuel from trucks and trailers.
(A)
All trucks and trailers shall be secure and all employees in the clear before
dumping is started.
(B) Personal
protective equipment necessary to protect workers from hazards shall be
provided and worn.
(C) Elevating
platform-type or cable-lift type unloading devices shall have adequate back
bumper stops.
(D) Side rails or
other positive means to prevent the truck and/or trailer from falling shall be
used while unloading the single trailer units.
(E) All persons shall be clear of all
hoisting or elevating mechanisms before dumping commences.
(F) No person shall remain in any truck while
the truck is being elevated.
(G) A
safe area and suitable device shall be provided for the chip tester to use
while taking chip samples.
(H)
Rolled chip nets shall not be positioned where they cover the ladders on rail
cars or trucks.
(I) Chip and hog
fuel storage.
(i) When mobile equipment is
used on top of hog fuel or chip piles, a roll-over protection system shall be
installed on the equipment. If the cab is of the enclosed type, windshield
wipers shall be installed.
(ii)
Hog fuel bins shall be provided with standard railed platform or walkways near
the top or other equally effective means shall be provided for use by employees
engaged in dislodging hog fuel.
(iii) Extreme care shall be taken to prevent
chips or hog fuel from creating an overhang or bridging.
(iv) Employees shall be prohibited from
working under overhangs or bridges.
(J) Chip and sawdust bins. Steam or
compressed-air lances, or other facilities, shall be used for breaking down the
arches caused by jamming in chip lofts. No worker shall be permitted to enter a
bin unless done in accordance with §1910.146, Permit-Required Confined
Spaces, in Subdivision J.
(i) Crane operations.
(A) Crane boom and load capacities as
specified by the manufacturer shall be posted in the cab of the crane in
accordance with §1910.180, Crawler, Locomotive and Truck Cranes, in
Subdivision N, Material Handling and Storage.
(B) A safety device such as a heavy chain or
cable at least equal in strength to the lifting cables shall be fastened to the
boom and to the frame of the boom crane (if it is other than locomotive) at the
base. Alternatively, a telescoping safety device shall be fastened to the boom
and to the cab frame, so as to prevent the boom from snapping back over the cab
in the event of lifting cable breakage.
(C) A crane shall not be operated where any
part thereof may come within 10 feet of overhead powerlines (or other overhead
obstructions) unless the powerlines have been de-energerized, or clearances are
maintained as specified in §1910.303, General Requirements, in Subdivision
S, Electrical.
(D) Standard
signals for the operation of cranes shall be established for all movements of
the crane, in accordance with American National Standards B30.2-1990 and
B30.8-1988.
(E) Only one member of
the crew shall be authorized to give signals to the crane operator.
(F) All cranes shall be equipped with a
suitable warning device such as a horn or whistle.
(G) A sheave guard shall be provided beneath
the head sheave of the boom.
(H)
Grapples, tongs, and buckets shall not be left suspended when not in use.
(j) Traffic warning
signs or signals.
(A) A flagger shall direct
the movement of cranes or locomotives being moved across railroad tracks or
roads, and at any points where the vision of the operator is restricted. The
flagger must always remain in sight of the operator when the crane or
locomotive is in motion. The blue flag policy shall be used to mark stationary
cars day and night. This policy shall include marking the track in advance of
the spotted cars (flag for daytime, light for darkness).
(B) After cars are spotted for loading or
unloading, warning flags or signs shall be placed in the center of the track at
least 50 feet away from the cars and a derail set to protect workers in or on
the car.
(k) Rail car
operations and railroad warning devices.
(A)
On a dead end spur, a blue signal may be displayed adjacent to the switch
opening while cars are being loaded or unloaded. When such warning devices are
displayed, the equipment shall not be coupled to or moved.
(B) Equipment which would obscure the blue
signal shall not be placed on the track.
(C) Each maintenance crew shall display and
remove its own set of blue signals.
(D) A flashing warning light or other device
shall be installed near any opening which leads to a passageway crossing
railroad tracks adjacent to the building. Such light or device shall be
activated prior to any switching or movement of railroad equipment to warn
workers of the dangerous condition in the area.
(E) Workers shall not crawl under or pass
between coupled rail cars to cross tracks.
(F) An audible whistle, horn, or bell shall
be sounded by the locomotive engineer to give adequate warning prior to
switching across any road crossing.
(G) When switching railroad equipment in
congested areas or across roadways or walkways, "flying switches" shall be
prohibited.
(H) All freight car
doors shall be inspected before workers open or close them. A safe method shall
be used to open or close the door.
(l) Illumination. Artificial illumination
shall be provided when loading or unloading is performed after dark, in
accordance with American National Standard ANSI/IES-RP-1990, Practice for
Industrial Lighting.
(m) Bridge or
dock plates.
(A) The construction and use of
bridge or dock plates shall conform to requirements of Subdivision D.
(B) The sides of bridge or dock
plates shall have an upturn or lip of at least 4 inches covering the area
between the edge of the loading dock and edge of car or truck floor whenever
the distance exceeds 18 inches to prevent wheeled equipment from running off
the sides.
(C) Bridge or dock
plates shall have at least 6 inches bearing surface on the loading dock.
(D) Bridge or dock plates intended
to be moved by mechanized equipment shall be designed for this purpose or
attachments for safe handling shall be used.
(n) Hand tools. Handles of wood hooks shall
be locked to the shank to prevent them from rotating.
(o) Removal of pulpwood.
(A) The ends of a woodpile shall be properly
sloped and cross-tiered into the pile. Upright poles shall not be used at the
ends of woodpiles. To knock down wood from the woodpile, mechanical equipment
shall be used to permit employees to keep in the clear of loosened wood.
(B) If dynamite is used to loosen
the pile, only authorized personnel shall be permitted to handle and discharge
the explosive. An electric detonator is preferable for firing; if a fuse is
used, it shall be an approved safety fuse with a burning rate of not less than
120 seconds per yard and a minimum length of 3 feet, in accordance with "Safety
in the Transportation, Storage, Handling and Use of Explosives", IME Pamphlet
No. 17, March 1987.
(p)
Log hauls, slips and carriages.
(A) Controls
shall be arranged to operate from a position where the operator will at all
times be in the clear of logs, machinery, lines, and rigging.
(B) Controls shall be marked to indicate
their function.
(C) An effective
method of disengaging the head rig saws from the power unit shall be installed
on all head rigs where the power unit is not directly controlled by the sawyer.
The saws shall be disengaged from the source of power which shall be locked out
before repairs or changes are made.
(D) When needed for protection of personnel,
an automatic stop or interlocking device shall be installed on log hauls or
slips.
(E) A barricade or other
positive stop of adequate strength shall be provided to protect the sawyer from
rolling logs.
(F) A guard shall be
provided to prevent logs from rolling off the log deck into the well.
(G) The sawyer shall be
safeguarded either by his or her location or by use of substantial screens or
approved safety glass.
(H) A
substantial stop or bumper shall be installed at each end of the carriage run.
(I) Canting gear or other
equipment shall not be allowed to hang over the log deck in such a manner as to
endanger employees.
(J) Canting
gear controls shall be marked to indicate their function.
(K) The sawyer shall be primarily responsible
for the safety of the carriage crew and offbearers. He or she shall exercise
due care in the operation of the carriage and log turning devices.
(L) A control device shall be provided so
that the sawyer may stop the head rig section of the mill without leaving his
or her stand.
(M) The feed control
lever of friction or belt-driven carriage feed works shall be designed to
operate away from the saws or carriage track.
(N) Feed works and log turning control levers
shall be so arranged that they may be secured when not in use and shall be
adequately guarded against accidental activation.
(O) Carriages upon which persons are required
to work shall be solidly decked over and the employees properly protected.
(P) Substantial sweeps shall be
installed in front of each carriage wheel. Such sweeps shall extend to within
1/4 inch of the rails.
(Q) Where
power-operated log turners are used, carriage knees shall be provided with
goosenecks or other substantial means of protecting the carriage crew.
(q) Belt conveyors.
(A) The sides of the conveyor shall be
constructed so that the pulpwood will not fall off.
(B) Where conveyors cross passageways or
roadways, a horizontal platform shall be provided under the conveyor extending
out from the sides of the conveyor a distance equal to 1 1/2 times the length
of the wood handled. The platform shall extend the width of the road plus 2
feet on each side and shall be kept free of wood and rubbish. The edges of the
platform shall be provided with toeboards or other protection to prevent wood
from falling, in accordance with American National Standard A10.18-1983.
(C) All conveyors for pulpwood
shall have the in-running nips between chain and sprockets guarded; also,
turning drums shall be guarded.
(D) Every belt conveyor shall have an
emergency stop cable extending the length of the conveyor so that it may be
stopped from any location along the line, or conveniently located stop buttons
within 10 feet of each work station, in accordance with American National
Standard ANSI/ASME B20.1-1993.
(r) Signs. Where conveyors cross walkways or
roadways in the yards, signs reading "Danger - Overhead Conveyor" or an
equivalent warning shall be erected, in accordance with American National
Standard for Safety Color Code, ANSI Z535.1-1991 or ANSI Z535.2-2011.
(5) Handling and
Storage of Raw Materials Other Than Pulpwood or Pulp Chips.
(a) Personal protective equipment.
(A) Whenever possible, all dust, fumes, and
gases incident to handling materials shall be controlled at the source, in
accordance with OAR 437-002-0382, Oregon Rules for
Air Contaminants, in Subdivision Z. Where control at the source is not
possible, respirators with goggles or protective masks shall be provided, and
employees shall wear them when handling alum, clay, soda ash, lime, bleach
powder, sulfur, chlorine, and similar materials, and when opening rag bales.
(B) When handling liquid acid or
alkali, workers shall be provided with approved eye and face protection and
protective clothing, in accordance with Subdivision I, Personal Protective
Equipment.
(b)
Clearance.
(A) When materials are being piled
inside a building and upon platforms, an aisle clearance at least 3 feet
greater than the widest truck in use shall be provided.
(B) Baled paper and rags stored inside a
building shall not be piled closer than 18 inches to walls, partitions, or
sprinkler heads.
(c)
Piling and unpiling pulp.
(A) Piles of wet
lap pulp (unless palletized) shall be stepped back one-half the width of the
sheet for each 8 feet of pile height. Sheets of pulp shall be interlapped to
make the pile secure. Pulp shall not be piled over pipelines to jeopardize
pipes, or so as to cause overloading of floors, or to within 18 inches below
sprinkler heads.
(B) Piles of pulp
shall not be undermined when being unpiled.
(C) Floor capacities shall be clearly marked
on all floors.
(d)
Chocking rolls.
(A) Where rolls are pyramided
two or more high, chocks shall be installed between each roll on the floor and
at every row. Where pulp and paper rolls are stored on smooth floors in
processing areas, rubber chocks with wooden core shall be used.
(B) When rolls are decked two or more high,
the bottom rolls shall be chocked on each side to prevent shifting in either
direction.
(6) Preparing Pulpwood.
(a) Gang and slasher saws. A guard shall be
provided in front of all gang and slasher saws to protect workers from wood
thrown by saws. A guard shall be placed over tail sprockets.
(b) Slasher tables. Saws shall be stopped and
power switches shall be locked out and tagged whenever it is necessary for any
person to be on the slasher table.
(c) Slasher drive belts, pulleys, and shafts.
All belts, pulleys, and shafts shall be guarded in accordance with American
National Standard ANSI/ASME B15.1-1992.
(d) Runway to the jack ladder. The runway
from the pond or unloading dock to the table shall be protected with standard
handrails and toeboards. Inclined portions shall have cleats or equivalent
nonslip surfacing, in accordance with Subdivision D, Walking-Working Surfaces.
Protective equipment shall be provided for persons working over water.
(e) Guards below table. Where not
protected by the frame of the machine, the underside of the slasher saws shall
be enclosed with guards.
(f)
Conveyors. The requirements of section (4)(q) of this rule shall apply.
(g) Circular saws (not slasher
saws). Saws shall be provided with standard guards, in accordance with American
National Standard ANSI O1.1-1992.
(h) Fixed chain saws, circular cut-off saws,
drag and swing saws.
(A) Saws shall be so
arranged that they will not project into any passageway when in an idle or
working position. When existing conditions do not leave clear passage the saws
shall be fenced off in order to make it impossible for anyone to walk into
them.
(B) Drag saws and fixed
chain saws shall be equipped with a device that will safely lock them in an
"UP" position.
(C) All persons
shall be in the clear before starting operations of a drag, chain, or swing
saw.
(D) Log decks shall be
equipped with a device to hold the material stable while being cut.
(i) Barker feed. Each barker shall
be equipped with a feed and turnover device which will make it unnecessary for
the operator to hold a bolt or log by hand during the barking operation. Eye,
ear, and head protection shall be provided for the operator, in accordance with
section (3)(c) of this rule.
(j)
Guards. A guard shall be installed around barkers to confine flying particles,
in accordance with ANSI/ASME B15.1-1992.
(k) Stops. All control devices shall be
locked out and tagged when knives are being changed.
(l) Speed governor. Water wheels, when
directly connected to barker disks or grinders, shall be provided with speed
governors, if operated with gate wide open.
(m) Continuous barking drums.
(A) When platforms or floors allow access to
the sides of the drums, a standard railing shall be constructed around the
drums. When two or more drums are arranged side by side, proper walkways with
standard handrails shall be provided between each set, in accordance with
section (3)(d) of this rule.
(B)
Sprockets and chains, gears, and trunnions shall have standard guards, in
accordance with section (3)(a) of this rule.
(C) Whenever it becomes necessary for a
worker to go within a drum, the driving mechanism shall be locked and tagged,
at the main disconnect switch, in accordance with section (3)(e) of this rule.
(D) This subsection (m) also
applies to barking drums employed in the yard.
(n) Intermittent barking drums. In addition
to motor switch, clutch, belt shifter, or other power disconnecting device,
intermittent barking drums shall be equipped with a device which may be locked
to prevent the drum from moving while it is being emptied or filled.
(o) Hydraulic barkers.
(A) Hydraulic barkers shall be enclosed with
strong baffles at the inlet and the outlet. The operator shall be protected by
at least five-ply laminated glass.
(B) The high pressure hoses of hydraulic
barkers shall be secured in such a manner that the hose connection ends will be
restrained if a hose connection fails.
(p) Splitter block. The block upon or against
which the wood is rested shall have a corrugated surface or other means
provided that the wood will not slip. Wood to be split, and also the splitting
block, shall be free of ice, snow, or chips. The operator shall be provided
with eye and foot protection. A clear and unobstructed view shall be maintained
between equipment and workers around the block and the workers' help area.
(q) Power control. Power for the
operation of the splitter shall be controlled by a clutch or equivalent device.
(r) Knot cleaners. The operators
of knot cleaners of the woodpecker type shall wear eye protection equipment.
(s) Chipper spout. The feed system
to the chipper spout shall be arranged in such a way that the operator does not
stand in a direct line with the chipper spout. All chipper spouts shall be
enclosed to a height of at least 42 inches from the floor or operator's
platform. When other protection is not sufficient, the operator shall be
protected from falling into the chipper by the use of a safety belt and
lanyard. Ear protection equipment shall be worn by the operator and others in
the immediate area if there is any possibility that the noise level may be
harmful (see §1910.95, Occupational Noise Exposure, in Subdivision G).
(t) Feeding material/clearing jams
in machines. Appropriate safety belts and lanyards and face protection shall be
used by employees who manually feed material or clear jams in machines unless
other provisions are made which will protect the employees.
(u) Carriers for knives. Carriers shall be
provided and used for transportation of knives.
(7) Rag and Old Paper Preparation.
(a) Ripping and trimming tools.
(A) Hand knives and scissors shall have blunt
points, shall be fastened to the table with chain or thong, and shall not be
carried on the person but placed safely in racks or sheaths when not in use.
(B) Hand knives and sharpening
steels shall be provided with guards at the junction of the handle and the
blade. Utility knives with blade exposure of 2-1/2 inches or less are exempted
from this requirement.
(b) Shredders, cutters, and dusters.
(A) Rotating heads or cylinders shall be
completely enclosed except for an opening at the feed side sufficient to permit
only the entry of stock. The enclosure shall extend over the top of the feed
rolls. It shall be constructed either of solid material or with mesh or
openings not exceeding 1/2-inch and substantial enough to contain flying
particles and prevent accidental contact with moving parts. The enclosure shall
be bolted or locked into place.
(B) A smooth-pivoted idler roll resting on
the stock or feed table shall be provided in front of feed rolls except when
arrangements prevent the operator from standing closer than 36 inches to any
part of the feed rolls.
(C) Any
manually fed cutter, shredder, or duster shall be provided with an idler roll
as per section (7)(b)(B) of this rule or the operator shall use special
hand-feeding tools.
(D) Hoods of
cutters, shredders, and dusters shall have exhaust ventilation, in accordance
with §1910.94, Ventilation, in Subdivision G.
(c) Blowers.
(A) Blowers used for transporting rags shall
be provided with feed hoppers having outer edges located not less than 48
inches from the fan.
(B) The
arrangement of the blower discharge outlets and work areas shall be such as to
prevent material from falling on workers.
(d) Conveyors. Conveyors and conveyor drive
belts and pulleys shall be fully enclosed or, if open and within 7 feet of the
floor, shall be constructed and guarded in accordance with section (4)(q) of
this rule, and Subdivision N, Material Handling and Storage.
(e) Guarding requirements.
(A) Traveling sections of conveyors and other
equipment with wheels which run on rails or guides shall be guarded by sweep
guards, installed in front of the traveling wheels in all areas where workers
may be exposed to contact. Sweep guards shall have not greater than 1/4 inch
clearance above the rail or guide.
(B) When using mechanical equipment to
elevate the front end of the chip containers for dumping into a hopper, the
shear area between the floor and the elevated section shall be safeguarded.
(f) Dust. Measures for
the control of dust shall be provided, in accordance with American National
Standard ANSI/NFPA 91-1992 and Subdivision I, Personal Protective Equipment.
(g) Rag cookers.
(A) When cleaning, inspection, or other work
requires that persons enter rag cookers, all steam and water valves, or other
control devices, shall be locked and tagged in the closed or "off" position.
Blank flanging of pipelines is acceptable in place of closed and locked valves.
(B) When cleaning, inspection, or
other work requires that persons must enter the cooker, one person shall be
stationed outside in a position to observe and assist in case of emergency, in
accordance with section (3)(f) of this rule.
(C) Rag cookers shall be provided with safety
valves in accordance with the ASME Boiler and Pressure Vessel Code, Section
VIII, Unfired Pressure Vessels - 1992.
(8) Chemical Processes of Making Pulp.
(a) Industrial kiln guns and ammunition.
Management shall develop written instructions, including safety procedures, for
storing and operating industrial kiln guns and ammunition. All persons working
with this equipment shall be instructed in these procedures and shall follow
them.
(b) Sulfur burners.
(A) Sulfur-burner houses shall be safely and
adequately ventilated, and every precaution shall be taken to guard against
dust explosion hazards and fires, in accordance with American National Standard
Z9.2-1979 (R1991), and NFPA 655-1993.
(B) Nonsparking tools and equipment shall be
used in handling dry sulfur.
(C)
Sulfur storage bins shall be kept free of sulfur dust accumulation, in
accordance with American National Standard ANSI Z9.2-1979 (R1991).
(D) Electric equipment shall be of the
explosion-proof type, in accordance with the requirements of Subdivision S,
Electrical.
(E) Sulfur-melting
equipment shall not be located in the burner room.
(c) Protection for employees (acid plants).
(A) Gas masks, fitted with canisters
containing absorbents for the particular acids, gases, or mists involved, shall
be provided for employees of the acid department.
(B) Supplied air respirators shall be
strategically located for emergency and rescue use.
(C) During inspection, repairs, or
maintenance of acid towers, the worker shall be provided with eye protection, a
supplied air respirator, a safety belt, and an attached lifeline. The line
shall be extended to an attendant stationed outside the tower opening.
(d) Acid tower
structure. Outside elevators shall be inspected daily during winter months when
ice materially affects safety. Elevators, runways, stairs, etc., for the acid
tower shall be inspected monthly for defects that may occur because of exposure
to acid or corrosive gases.
(e)
Tanks (acid). Entering acid tanks shall be in accordance with
437-002-0146 Confined Spaces, in
Subdivision J.
(f) Clothing. Where
lime slaking takes place, employees shall be provided with rubber boots, rubber
gloves, protective aprons, and eye protection. A deluge shower and eye fountain
shall be provided to flush the skin and eyes to counteract lime or acid burns.
(g) Lead burning. When lead
burning is being done within tanks, fresh air shall be forced into the tanks so
that fresh air will reach the face of the worker first and the direction of the
current will never be from the source of the fumes toward the face of the
workers. Supplied air respirators (constant-flow type) shall be provided.
NOTE: (For specifics refer to Subdivision Q, Welding, Cutting and Brazing; and §1910.1025, Lead, in Subdivision Z.)
(h) Hoops for acid storage tanks. Hoops of
tanks shall be made of rods rather than flat strips and shall be safely
maintained by scheduled inspections.
(i) Quicklime stoppages. Water shall not be
used to unplug quicklime stops or plugs in pipes or confined spaces.
(j) Digester building exits. At least one
unobstructed exit at each end of the room shall be provided on each floor of a
digester building.
(k) Digester
building escape respirators. Escape respirators shall be available for escape
purposes only. These respirators shall meet the requirements of §1910.134
in Subdivision I, including the requirement to be inspected at frequent
intervals, not to exceed one month.
(l) Elevators.
(A) Elevators shall be constructed in
accordance with American National Standard A17.1-1990.
(B) Elevators shall be equipped with escape
respirators for the maximum number of passengers.
(C) Elevators shall be equipped with an alarm
system to advise of failure.
(m) Blowoff valves and piping.
(A) The blowoff valve of a digester shall be
arranged so as to be operated from another room, remote from safety valves.
(B) All fasteners used to secure
digester piping shall conform to ANSI/ASME B31.1-1992.
(C) Digester blow valves shall be pinned or
locked in closed position throughout the entire cooking period. This rule
applies only to manually operated valves in batch digestors.
(n) Blow lines.
(A) When blow lines from more than one
digester lead into one pipe, the cock or valve of the blow line from the tank
being inspected or repaired shall be locked and tagged out, or the line shall
be disconnected and blocked off.
(B) Test holes in piping systems. Test holes
in blow lines of piping systems shall not be covered with insulation or other
materials.
(o)
Inspection and repair of tanks. All piping leading to tanks shall be blanked
off or valved and locked in accordance with §1910.147, Lockout/Tagout, in
Subdivision J.
(p) Blow pits and
blow tanks.
(A) Blow-pit openings shall be
preferably on the side of the pit instead of on top. When located on top,
openings shall be as small as possible and shall be provided with railings, in
accordance with Subdivision D, Walking-Working Surfaces.
(B) Entrance into blow pits must be done in
accordance with 437-002-0146, Subdivision J.
(C) A signaling device shall be
installed in the digester and blow-pit rooms and chip bins to be operated as a
warning before and while digesters are being blown.
(D) Blow-pit hoops shall be maintained in a
safe condition.
(q)
Blowing batch digester.
(A) Blowoff valves
shall be opened slowly.
(B) After
the digester has started to be blown, the blowoff valve shall be left open, and
the hand plate shall not be removed until the digester cook signals the blowpit
person that the blow is completed. Whenever it becomes necessary to remove the
hand plate to clear stock, operators shall wear eye protection equipment and
protective clothing to guard against burns from hot stock.
(C) Means shall be provided whereby the
digester cook shall signal the person in the chip bin before starting to load
the digester.
(r)
Inspecting and repairing digester.
(A) Valves
controlling lines leading into a digester shall be locked out and tagged in
accordance with §1910.147, Lockout/Tagout, in Subdivision J.
(B) Sources of energy associated with a
digester shall be isolated in accordance with §1910.147, Lockout/Tagout,
in Subdivision J.
(C) Entry into
the digester shall be in accordance with
437-002-0146 Confined Spaces, in
Subdivision J.
(D) The
concentration of lead in the air shall not exceed the limits specified in
§1910.1025, Lead, Subdivision Z.
(E) All employees entering digesters for
inspection or repair work shall be provided with protective headgear.
(F) Eye protection and dust
respirators shall be provided to workers while the old brick lining is being
removed, in accordance with Subdivision I, Personal Protective Equipment.
(G) Sanitary facilities shall be
provided as specified in §1910.141, Sanitation, in Subdivision J.
(s) Pressure
tanks-accumulators (acid).
(A) Safety
regulations governing inspection and repairing of pressure tanks-accumulators
(acid) shall be the same as those specified in section (8)(t) of this rule.
(B) The pressure
tanks-accumulators shall be inspected twice annually and more frequently if
required by the manufacturer or engineer's recommendations. (Refer to Boiler
and Pressure Vessel Safety Laws of the State Building Codes Division,
Department of Consumer and Business Services.)
(t) Pressure vessels (safety devices).
(A) Each unfired pressure vessel shall have a
pressure relieving device or devices installed and operated in accordance with
ASME Boiler and Pressure Vessel Code, Section VIII (Unfired Pressure Vessels -
1992). In the case of batch digesters with safety pressure relieving devices
installed directly to the pressure vessel, means shall be devised to verify
regularly that the safety devices have not become plugged or corroded to the
point of being inoperative.
(B)
All safety devices shall conform to Paragraph U-2 in the ASME Boiler and
Pressure Vessel Code, Section VIII, Unfired Pressure Vessels - 1992.
(u) Miscellaneous. Insofar as the
processes of the sulfate and soda operations are similar to those of the
sulfite processes, sections (8)(a) through (t) of this rule shall apply.
(A) Quick operating showers, bubblers, etc.,
shall be available for emergency use in case of caustic soda burns.
(B) Rotary tenders, smelter operators, and
those cleaning smelt spouts shall be provided with eye protection equipment
(fitted with lenses that filter out the harmful rays emanating from the light
source) when actively engaged in their duties, in accordance with OAR
437-002-0134, in Subdivision I.
(C) Piping, valves and fittings
between the digester, blowpit, and blow tanks shall be in accordance with
ANSI/ASME B31.1-1992. These shall be inspected at least semi-annually to
determine the degree of deterioration and repaired or replaced when necessary,
in accordance with American National Standards ANSI/ASME B31.1-1992.
(v) Welding. Welding on blow
tanks, accumulator tanks, or any other vessels where turpentine vapor or other
combustible vapor could gather shall be done only after the vessel has been
completely purged of fumes. Fresh air shall be supplied workers inside of
vessels.
NOTE: See Subdivision Q, Welding, Cutting and Brazing, for additional welding requirements.
(w) Turpentine systems and storage tanks.
Nonsparking tools and ground hose shall be used when pumping out the tank. The
tank shall be surrounded by a berm or moat.
(x) Recovery furnace area.
(A) An audible warning system shall be
installed in kraft and soda base sulfite recovery furnace areas and shall be
activated whenever an emergency exists.
(B) All personnel working in recovery furnace
areas shall be instructed on procedures to be followed when emergency warning
systems are activated.
(C)
Emergency warning systems in the recovery furnace areas shall be kept in proper
working condition and shall be tested or checked weekly.
(D) Workers shall stand to the side while
opening a furnace or boiler firebox door.
(E) Smelt-dissolving tanks shall be covered
and the cover kept closed, except when samples are being taken.
(F) Smelt tanks shall be provided with vent
stacks and explosion doors, in accordance with American National Standard
ANSI/UL 641-1985.
(G) An emergency
shutdown procedure as currently recommended by the boiler manufacturer shall be
implemented and used when an emergency shutdown is required. Both normal and
emergency shutdown procedures shall be posted.
(H) Recovery furnaces and power boilers are
to be constructed, maintained, and serviced as required by the State Building
Codes Division of the Department of Consumer and Business Services.
(I) Open pipes shall not be used as punch
bars if the use would create a hazard.
(J) Furnace room. Exhaust ventilation shall
be provided where niter cake is fed into a rotary furnace and shall be so
designed and maintained as to keep the concentration of hydrogen sulfide gas
below the limits listed in OAR
437-002-0382, Oregon Rules for
Air Contaminants, in Subdivision Z.
(9) Bleaching.
(a) Bleaching containers. Bleaching
containers, such as cells, towers (bleaching engines), etc., except the Bellmer
type, shall be completely covered on the top, with the exception of one small
opening large enough to allow filling but too small to admit a person.
Platforms leading from one engine to another shall have standard guardrails, in
accordance with Subdivision D, Walking-Working Surfaces.
(b) Bleach plant alarm system. An audible
alarm system shall be installed and it shall be activated whenever a serious
leak or break develops in the bleach plant area which creates a health or fire
hazard.
(c) Bleach mixing rooms.
(A) Areas where dry bleach powder is mixed
shall be provided with adequate exhaust ventilation, located at the floor
level, in accordance with ANSI/UL 641-1985.
(B) Respiratory protection shall be provided
for emergency use, in accordance with American National Standards ANSI/NFPA
1404-1989, and Z88.2-1980. Respiratory protection must conform to the
requirements of §1910.134 of Subdivision I.
(C) For emergency and rescue work,
self-contained air masks or supplied air equipment shall be provided in
accordance with American National Standards Z88.2-1980. Respiratory protection
must conform to the requirements of §1910.134 of Subdivision I.
(d) Liquid chlorine.
(A) Tanks of liquid chlorine shall be stored
in an adequately ventilated unoccupied room, where their possible leakage
cannot affect workers.
(B) Gas
masks capable of absorbing chlorine shall be supplied, conveniently placed, and
regularly inspected, and workers who may be exposed to chlorine gas shall be
instructed in their use.
(C) For
emergency and rescue work, independent self-contained breathing apparatus or
supplied air equipment shall be provided.
(D) At least two exits, remote from each
other, shall be provided for all rooms in which chlorine is stored.
(E) Spur tracks upon which tank cars
containing chlorine and caustic are spotted and connected to pipelines shall be
protected by means of a derail in front of the cars.
(F) All chlorine, caustic, and acid lines
shall be marked for positive identification, in accordance with American
National Standard A13.1-1981 (R 1985).
(e) Handling chlorine dioxide.
(A) Chlorine dioxide generating and storage
facilities shall be placed in areas which are adequately ventilated and are
easily kept clean of wood, paper, pulp, etc., to avoid contamination which
might cause a reaction. This can be accomplished by placing these facilities in
a separate room or in a designated outside space.
(B) Safety showers and/or jump tanks and
eyewash fountains shall be provided for persons working around sodium chlorate
and the other hazardous chemicals involved in this process.
(C) Water hoses for flushing spills shall be
adequate in size and located where needed.
(D) The generating area shall have signs in
accordance with Subdivision J, General Environmental Controls, warning of the
hazard and restricting entrance to authorized personnel only.
(E) Facilities handling sodium chlorate and
chlorine dioxide shall be declared "No Smoking" areas and shall have signs
posted accordingly.
(F) All
equipment involved in the chlorine dioxide process where pressure may be
generated shall be provided with adequate pressure relief devices.
(G) Respiratory protective equipment approved
for use in exposures to chlorine and chlorine dioxide gases shall be provided.
(H) Management shall be
responsible for developing written instructions including safety procedures for
operating and maintaining the generator and associated equipment. All personnel
working on this equipment shall be thoroughly trained in these procedures and
shall follow them.
(I) Only
authorized personnel shall be allowed in close proximity to the chlorine
dioxide generating equipment.
(J)
When reasonably possible, the sample station should be located on the outside
of the generating room. Goggles must be worn when taking samples.
(K) Welding or burning shall not be performed
on the generator system while it is operating. Immediately before maintenance
can be performed on the inside of any of this equipment, it shall be thoroughly
flushed with water and purged of hazardous gases.
(L) Chlorine and chlorine dioxide gas shall
be carried away from the work place and breathing area by an exhaust system.
The gas shall be rendered neutral or harmless before being discharged into the
atmosphere. The requirements of American National Standard Z9.2-1979 (R1991)
shall apply to this subdivision.
(f) Handling sodium chlorate.
(A) Workers handling and working with sodium
chlorate shall be thoroughly trained in precautions to be used in handling and
special work habits.
(B) Workers
exposed to direct contact with sodium chlorate shall wear appropriate personal
protective equipment.
(C)
Facilities for storage and handling of sodium chlorate shall be constructed so
as to eliminate possible contact of dry or evaporated sodium chlorate with wood
or other material which could cause a fire or explosion.
(D) Chlorine gas shall be carried away from
the work place and breathing area by an exhaust system. The gas shall be
rendered neutral or harmless before being discharged into the atmosphere. The
requirements of American National Standard Z9.2-1979 (R1991) shall apply to
this subdivision.
(E) Sodium
chlorate facilities shall be constructed with a minimum of packing glands,
stuffing boxes, etc.
(g) Bagged or drummed chemicals. Bagged or
drummed chemicals require efficient handling to prevent damage and spillage.
Certain oxidizing chemicals used in bleaching pulp and also in some sanitizing
work require added precautions for safety in storage and handling. In storage,
these chemicals shall be isolated from combustible materials and other
chemicals with which they will react such as acids. They shall also be kept
dry, clean and uncontaminated.
(10) Mechanical Pulp Process.
(a) Pulp grinders.
(A) Water wheels directly connected to pulp
grinders shall be provided with speed governors limiting the peripheral speed
of the grinder to that recommended by the manufacturer.
(B) Doors of pocket grinders shall be
arranged so as to keep them from closing accidentally.
(b) Butting saws. Hood guards shall be
provided on butting saws, in accordance with American National Standard ANSI
O1.1-1992.
(c) Floors and
platforms. The requirements of section (3)(d) of this rule shall apply.
(d) Personal protection. Persons
exposed to falling material shall wear eye, head, foot, and shin protection
equipment, in accordance with Subdivision I, Personal Protective Equipment.
(11) Stock Preparation.
(a) Pulp shredders.
(A) Cutting heads shall be completely
enclosed except for an opening at the feed side sufficient to permit only entry
of stock. The enclosure shall be bolted or locked in place. The enclosure shall
be of solid material or with mesh or other openings not exceeding 1/2-inch.
(B) Either a slanting feed table
with its outer edge not less than 36 inches from the cutting head or an
automatic feeding device shall be provided.
(C) Repairs for cleaning of blockage shall be
done only when the shredder is shutdown and control devices locked.
(D) All power-driven mechanisms shall be
guarded in accordance with section (3)(a) of this rule.
(b) Pulp conveyors. Pulp conveyors and
conveyor drive belts and pulleys shall be fully enclosed, or if open and within
7 feet of the floor, shall be constructed and guarded in accordance with
Subdivision N, Material Handling and Storage, and Subdivision O, Machinery and
Machine Guarding.
(c) Floors,
steps, and platforms. The requirements of section (3)(d) of this rule shall
apply.
(d) Beaters.
(A) Beater rolls shall be provided with
covers.
(B) Guardrails 42 inches
high shall be provided around beaters where tub tops are less than 42 inches
from the floor, in accordance with section (3)(d) of this rule and Subdivision
D, Walking-Working Surfaces.
(C)
When cleaning, inspecting, or other work requires that persons enter the
beaters, all control devices shall be locked and tagged out, in accordance with
§1910.147, Lockout, in Subdivision J.
(D) When beaters are fed from the floor
above, the chute opening, if less than 42 inches from the floor, shall be
provided with a complete rail or other enclosure. Openings for manual feeding
shall be sufficient only for entry of stock and shall be provided with at least
two permanently secured crossrails, in accordance with Subdivision D,
Walking-Working Surfaces.
(E)
Floors around beaters shall be provided with sufficient drainage to remove
wastes.
(e) Pulpers.
(A) All pulpers having the top or any other
opening of the vessel less than 42 inches from the floor or work platform shall
have such openings guarded by railed or other enclosures. For manual charging,
openings shall be sufficient only to permit the entry of stock and shall be
provided with at least two permanently secured crossrails, in accordance with
Subdivision D.
(B) When cleaning,
inspecting or other work requires persons to enter the pulpers it shall be in
accordance with 437-002-0146 Confined Spaces, in
Subdivision J. All power mechanisms shall be guarded as required in Subdivision
O, Machinery and Machine Guarding.
(C) Cleaning or inspecting pulpers or other
work, including work above the pulper in a dangerous position, shall be in
accordance with §1910.147, Lockout, in Subdivision J.
(D) All power mechanisms shall be guarded in
accordance with Subdivision O, Machinery and Machine Guarding.
(f) Pulping devices. Emergency
stop controls shall be provided at the feed point when pulping devices are fed
manually from the floor above.
(g)
Guillotine-type roll splitters. Rolls shall be centered and in a horizontal
position directly below the guillotine-type blade while being split. No part of
the body shall be under the guillotine-type blade.
(h) Stock chests and tanks.
(A) All control devices shall be locked when
persons enter stock chests, in accordance with §1910.147, Lockout/Tagout,
in Subdivision J.
(B) All power
mechanisms shall be guarded in accordance with Subdivision O, Machinery and
Machine Guarding.
(C) When
cleaning, inspecting, or other work requires that persons enter stock chests,
they shall be provided with a low-voltage extension light.
(12) Machine Room.
(a) Controls and safety devices.
(A) Electrically or manually operated power
disconnecting devices for all power-operated equipment shall be provided within
easy reach of the operator while in his or her normal operating position. If
necessary for safety of the operation, the machine shall be so equipped that
retarding or braking action can be applied at the time of or after the source
of power is deactivated.
(B) Pulp
and paper machines shall be equipped with stopping devices. The devices shall
be located where they can be used readily to stop the machines or sections of
the machine. Power disconnect devices and retarding or braking controls
provided for in section (12)(a)(A) of this rule are required for the safe
operation of a pulp and paper machine.
(C) Brakes, back stops, antirunaway devices,
overload releases, and other safety devices shall be inspected and tested
frequently to insure that all are operative and maintained in good repair.
(D) An audible alarm shall be
sounded prior to starting up any section of a pulp or paper machine. Sufficient
time shall be allowed between activation of the alarm system and start-up of
the equipment to allow any persons to clear the hazardous area.
(E) In starting up a dryer section, dryers
shall be preheated and steam for heating the drums shall be introduced slowly,
while the drums are revolving.
(F)
Employees shall not attempt to remove a broken carrier rope from a dryer while
the section is running at operating speed.
(G) Employees shall not feed a stack with any
hand-held device which is capable of going through the nip.
(H) Employees shall stop dryer to remove a
wrap except in cases where it can be safely removed by using air or other safe
means.
(I) Special protective
gloves shall be provided and shall be worn by employees when filing or handling
sharp-edged doctor blades.
(J)
Employees shall not place their hands between the sharp edge of an unloaded
doctor blade and the roll while cleaning the doctor blade.
(K) The crane operator shall ascertain that
reels are properly seated at winder stand or at reel arms before he or she
disengages the hooks.
(L)
Shaftless winders shall be provided with a barrier guard of sufficient strength
and size to confine the rolls in the event they become dislodged while running.
(M) Employees shall keep clear of
hazardous areas around the lowerator, especially all lowerator openings in a
floor and where roll is being discharged.
(N) If a powered roll ejector is used it
should be interlocked to prevent accidental actuation until the receiving
platform or roll lowering table is in position to receive the roll.
(O) Provision shall be made to hold the rider
roll when in a raised position unless counterbalancing eliminates the hazard.
(b) Drives.
(A) All drives, pulleys, couplings, and
shafts on equipment requiring service while operating shall have standard
guards in accordance with section (3)(a) of this rule.
(B) All drives shall be provided with lockout
devices at the power switch which interrupts the flow of current to the unit.
(C) All ends of rotating shafts
including dryer drum shafts shall be completely guarded.
(D) All accessible disengaged doctor blades
should be covered.
(E) All exposed
shafts shall be guarded. Crossovers shall be provided.
(F) Oil cups and grease fittings shall be
placed in a safe area remote from nip and heat hazards.
(c) Protective equipment. Face shields,
aprons and rubber gloves shall be provided for workers handling acids in
accordance with sections (3)(c) and (5)(a) of this rule.
(d) Walkways. Steps and footwalks along the
fourdrinier and press section shall have nonslip surfacing and be complete with
standard handrails, when practical, in accordance with Subdivision D,
Walking-Working Surfaces.
(e)
Steps. Steps of uniform rise and tread with nonslip surfaces shall be provided
at each press in accordance with Subdivision D, Walking-Working Surfaces.
(f) Plank walkways. A removable
plank shall be provided along each press, with standard guardrails installed.
The planks shall have nonslip surfaces in accordance with Subdivision D,
Walking-Working Surfaces.
(g)
Dryer lubrication. If a gear bearing must be oiled while the machine is in
operation, an automatic oiling device to protect the oiler shall be provided,
or oil cups and grease fittings shall be placed along the walkways out of reach
of hot pipes and dryer gears.
(h)
Levers. All levers carrying weights shall be constructed so that weights will
not slip or fall off.
(i) First
dryer. Either a permanent guardrail or apron guard or both shall be installed
in front of the first dryer in each section in accordance with Subdivision O,
Machinery and Machine Guarding.
(j) Steam and hot-water pipes. All exposed
steam and hot-water pipes within 7 feet of the floor or working platform or
within 15 inches measured horizontally from stairways, ramps, or fixed ladders
shall be covered with an insulating material, or guarded in such manner as to
prevent contact.
(k) Dryer gears.
Dryer gears shall be guarded except where the oilers' walkway is removed out of
reach of the gears' nips and spokes and hot pipes in accordance with
Subdivision O, Machinery and Machine Guarding.
(l) Broke hole.
(A) A guardrail shall be provided at broke
holes in accordance with Subdivision D, Walking-Working Surfaces.
(B) Where pulpers are located directly below
the broke hole on a paper machine and where the broke hole opening is large
enough to permit a worker to fall through, any employee pushing broke down the
hole shall wear a safety belt and lanyard. The lanyard shall be fastened in
such a manner that it is impossible for the person to fall into the pulper.
(C) An alarm bell or a flashing
light shall be actuated before dropping material through the broke hole.
(m) Feeder belt. A
feeder belt or other effective device shall be provided for starting paper
through the calender stack.
(n)
Steps. Steps or ladders of uniform rise and tread with nonslip surfaces shall
be provided at each calender stack. Handrails and hand grips shall be provided
at each calender stack in accordance with Subdivision D, Walking-Working
Surfaces.
(o) Grounding. All
calender stacks and spreader bars shall be grounded in accordance with
Subdivision S, Electrical, as protection against shock induced by static
electricity.
(p) Sole plates. All
exposed sole plates between dryers, calenders, reels, and rewinders shall have
a nonskid surface.
(q) Nip points.
The hazard of the nip points on all calender rolls shall be eliminated or
minimized by means of an effective barrier device, or by feeding the paper into
the rolls by means of a rope carrier, air jets, or hand feeding devices.
(r) Scrapers. Alloy steel scrapers
with pullthrough blades approximately 3 by 5 inches in size shall be used to
remove "scabs" from calender rolls.
(s) Illumination. Permanent lighting shall be
installed in all areas where employees are required to make machine adjustments
and sheet transfers in accordance with American National Standard ANSI/IES
RP-1990.
(t) Control panels. All
control panel handles and buttons shall be protected from accidental contact.
(u) Lifting reels.
(A) The reels shall stop rotating before
being lifted from bearings.
(B)
All lifting equipment (clamps, cables, and slings) shall be maintained in a
safe condition and inspected regularly.
(C) Reel shafts with square block ends shall
be guarded.
(v) Feeder
belts. Feeder belts, carrier ropes, air carriage, or other equally effective
means shall be provided for starting paper into the nip or drum-type reels.
(w) In-running nip.
(A) Where the nipping points of all drum
winders and rewinders is on the operator's side, it shall be guarded by barrier
guards interlocked with the drive mechanism.
(B) A zero speed switch or locking device
shall be installed to prevent the guard from being raised, lowered, or removed
while the roll is turning.
(x) Core collars. Set screws for securing
core collars to winding and unwinding shafts shall not protrude above the face
of the collar. All edges of the collar with which an operator's hand comes in
contact shall be beveled to remove all sharp corners.
(y) Slitter knives. Slitter knives shall be
guarded so as to prevent accidental contact. Carriers shall be provided and
used for transportation of slitter knives.
(z) Winder shaft. The winder shall have a
guide rail to align the shaft for easy entrance into the opened rewind shaft
bearing housings.
(aa) Handling
rolls, winders and core shafts. Mechanical handling equipment shall be provided
for handling rolls, winder shafts, and core shafts that are too heavy for safe
manual handling based on the NIOSH Work Practice Guide for Manual Lifting -
1981.
(bb) Winder area. A nonskid
surface shall be provided in front of the winder to prevent accidental
slipping.
(cc) Radiation. Special
standards regarding the use of radiation equipment shall be posted and followed
as required by §1910.1096, Ionizing Radiation, in Subdivision Z.
(13) Finishing Room.
(a) Cleaning rolls. Rolls shall be cleaned
only on the outrunning side.
(b)
Emergency stops. Electrically or manually operated quick power disconnecting
devices, interlocked with braking action, shall be provided on all operating
sides of the machine within easy reach of all employees. These devices shall be
tested by making use of them when stopping the machine.
(c) Core collars. The requirements of section
(12)(x) of this rule, and the requirements in Subdivision O, Machinery and
Machine Guarding, shall apply.
(d)
Elevators. These shall be in accordance with American National Standard
ANSI/ASME A17.1-1990.
(e) Control
panels. The requirements of section (12)(t) of this rule shall apply.
(f) Guillotine-type cutters.
(A) Each guillotine-type cutter shall be
equipped with a control which requires the operator and helper, if any, to use
both hands to engage the clutch when operated from within reach of blade.
(B) Each guillotine-type cutter
shall be equipped with a nonrepeat device.
(C) Carriers shall be provided and used for
transportation of guillotine-type cutter knives.
(g) Rotary cutter.
(A) On single-knife machines a guard shall be
provided at a point of contact to the knife.
(B) On duplex cutters the protection required
for single-knife machines shall be provided for the first knife, and a hood
shall be provided for the second knife.
(C) Safe access shall be provided to the
knives of a rotary cutter by means of catwalks with nonslip surfaces, railings,
and toeboards in accordance with Subdivision D, Walking-Working Surfaces.
(D) A guard shall be provided for
the spreader or squeeze roll at the nip side on sheet cutters.
(E) Electrically or manually operated quick
power disconnecting devices with adequate braking action shall be provided on
all operating sides of the machine within easy reach of all operators.
(F) The outside slitters shall be
guarded.
(h) Platers.
(A) A guard shall be arranged across the face
of the rolls to serve as a warning that the operator's hand is approaching the
danger zone.
(B) A quick power
disconnecting device shall be installed on each machine within easy reach of
the operator.
(i)
Finishing room rewinders.
(A) The nipping
points of all drum winders and rewinders located on the operator's side shall
be guarded by either automatic or manually operated barrier guards of
sufficient height to protect fully anyone working around them. The barrier
guard shall be interlocked with the drive mechanism to prevent operating above
jog speed without the guard in place. A zero speed switch should be installed
to prevent the guard from being raised while the roll is turning.
(B) A nonskid surface shall be provided in
front of the rewinder to prevent an employee from slipping in accordance with
section (3)(d) of this rule.
(C)
Mechanical lifting devices shall be provided for placing and removing rolls
from the machine.
(j)
Control panels. The requirements of section (12)(t) of this rule shall apply.
(k) Roll-type embosser. The
nipping point located on the operator's side shall be guarded by either
automatic or manually operated barrier guards interlocked with the drive.
(l) Converting machines.
(A) When using a crane or hoist to place
rolls into a backstand and the operator cannot see both ends of the backstand,
appropriate means will be implemented to eliminate hazards involved. The
operator shall ascertain that rolls are properly seated at winder stand or at
roll arms before he or she disengages the hooks.
(B) All power closing sections shall be
equipped with an audible warning system which will be activated when closing
the sections.
(C) Slitters,
slotters, and scorers not in use shall be properly stored so as not to create a
hazard.
(D) Mechanical handling
equipment shall be provided for handling rolls or devices that are too heavy
for safe manual handling based on the NIOSH Work Practice Guide for Manual
Lifting - 1981.
(E) Sheer and
pinch points. Sheer and pinch points at the feed mechanism shall be color-coded
orange and/or identified by signs in accordance with Subdivision J, General
Environmental Controls.
(m) Sorting and counting tables.
(A) Tables shall be smooth and free from
splinters, with edges and corners rounded.
(B) Paddles shall be smooth and free from
splinters.
(n) Roll
splitters. The nip point and cutter knife shall be guarded by either automatic
or manually operated barrier guards.
(o) Corrugators.
(A) Rails of rail-mounted devices such as
roll stands shall be flush with the adjacent floor, and so installed to provide
a minimum of 18 inches clearance between the equipment and walls or other fixed
objects.
(B) All corrugating and
pressure rolls shall be equipped with appropriately designed and installed
threading guides so as to prevent contact with the infeed nip of the various
rolls by the operator.
(C) Lower
elevating conveyor belt rolls on the single facer bridge shall have a minimum
nip clearance of 4 inches.
(D) Web
shears at the discharge end of the double facer shall be equipped with
barrier-type guards.
(E) Slitter
stations not in use shall be disconnected from the power source by positive
means.
(F) The adhesive system
shall be so designed and installed as to keep fumes and airborne dust within
limits in accordance with OAR
437-002-0382, Oregon Rules for
Air Contaminants, in Subdivision Z.
(14) Materials Handling.
(a) Hand trucks. No person shall be permitted
to ride on a powered hand truck unless it is so designed by the manufacturer. A
limit switch shall be on operating handle - 30° each way from a 45°
angle up and down.
(b) Power
trucks. Power trucks shall comply with Subdivision N, Material Handling and
Storage. Adequate ventilation shall be provided and the trucks properly
maintained, so that dangerous concentrations of carbon monoxide cannot be
generated, especially in warehouses or other isolated areas of a plant.
(c) Carton-stitching machine. The
carton-stitching machine shall be guarded to prevent the operator from coming
in contact with the stitching head.
(d) Banding of skids, cartons, cases, etc.
Banders and helpers shall wear eye protection equipment in accordance with
section (3)(c) of this rule.
(e)
Unloading cars or trucks.
(A) Loading and
unloading materials. Platforms with ladders or stairways shall be installed or
alternative methods made available when needed so that workers may safely gain
access to and perform work on the top of rail cars or trucks when ladders are
not installed on such equipment.
(B) Where steel bands or wires are used in
boxcars or trucks, all loaders and helpers shall wear eye protection in
accordance with Subdivision I, Personal Protective Equipment.
(C) The construction and use of bridge or
dock plates shall conform to the requirements of American National Standard
B56.1-1988.
(D) Flag signals,
derails, or other protective devices shall be used to protect workers during
switching operations. The blue flag policy shall be invoked according to
section (4)(j) of this rule.
Notes
Stat. Auth.: ORS 654.025(2) & 656.726(4)
Stats. Implemented: ORS 654.001 - 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.