Or. Admin. Code § 437-004-0310 - Working Surfaces
(1)
Scope. This section applies to all places of agricultural employment. Measures
to control toxic materials are outside the scope of this section.
(2) Housekeeping. Floors, work areas, aisles
and passageways must be in good repair and must not have protruding nails,
unevenness, obstructions, debris or loose boards that create a
hazard.
(3) Aisles, walkways,
inclines and passageways.
(a) There must be
sufficient clearance for safe operation of mechanical handling equipment in
aisles, at loading docks, through doorways and at turns. Aisles and passageways
must be clear and in good repair with no obstructions that could be a
hazard.
(b) Mark permanent aisles
and passageways.
(c) Aisles,
passageways, and walkways must be wide enough for safe work but never less than
22 inches wide. Passageways more than 4 feet above the ground or floor level
must have standard guardrails.
(d)
Fixed inclined walkways must be at least 22 inches wide, incline at no more
than 24 degrees and be securely fastened at the top and bottom. They must have
guardrails on each open side.
(e)
Inclined walkways that may be slippery must have anti-slip surfaces or cleats
secured at uniform intervals of not more than 18 inches, and extending the full
width of the walkway.
(f) Inclines
from floor to floor, without open sides, used instead of stairways must have
standard railings according to the requirements for stairways.
(g) Ramps for wheelbarrows, if made of
planking, must have an odd number of planks with no cleats on the center
plank.
(4) Covers and
guardrails. There must be covers and/or guardrails to protect people from the
hazards of open pits, tanks, vats, excavations, etc.
(5) Surface loads. For all new and remodel
construction after December 1, 1997, post the load capacities on overhead
storage areas. Do not allow overloading.
(6) Barriers. There must be protective
barriers or suitable guards for uncovered openings or excavations that are
accessible to vehicle or pedestrian traffic. Use warning lights or flares if
working at night.
(7) Vertical
clearances. There must be a vertical clearance of at least 6 1/2 feet over work
areas. Where it is impractical to provide this clearance, use padding,
contrasting paint or similar warnings on overhead obstructions.
NOTE: This does not apply to crop storage areas where people are there for short periods.
(8) Working above other workers. Areas above
other workers, for handling or mixing acids, caustics, or other harmful
materials must have water-tight floors that drain to a safe location, except
where workers underneath wear personal protective equipment suitable for the
hazard.
Notes
Stat. Auth.: ORS 654.025(2) & ORS 656.726(3)
Stats. Implemented: ORS 654.001 - ORS 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.