Or. Admin. Code § 437-004-2400 - Arc Welding and Cutting
(1) Scope. This subdivision applies to
agricultural welding, except the following types that are covered by
Subdivision 2/Q:
(a) Production type or amount
of welding.
(b) Welding in confined
spaces like tanks, vats, pits, or those defined in 4/J, OAR
437-004-1250(1).
This section (4/Q) covers some confined space welding topics. In those cases,
follow this section in addition to the rules in 2/Q.
(c) Welding with toxic or dangerous coatings
or fluxes. This includes manganese, lead, zinc, cadmium, mercury, beryllium, or
fluorine compounds.
(d) Welding or
heating galvanized materials.
(2) Instruction. Only trained and qualified
workers will be allowed to run arc welding equipment.
(3) Application of arc welding equipment.
(a) General. Equipment that complies with the
Requirements for Electric Arc-Welding Apparatus, NEMA EW-1-1983, National
Electrical Manufacturers Association or the Safety Standard for
Transformer-Type Arc-Welding Machines, ANSI/UL 551, 1993, Underwriters'
Laboratories assures consideration of safety in design.
(b) Voltage. Do not exceed the following
limits:
(A) Alternating-current machines.
(i) Manual arc welding and cutting - 80
volts.
(ii) Automatic (machine or
mechanized) arc welding and cutting - 100 volts.
(B) Direct-current machines.
(i) Manual arc welding and cutting - 100
volts.
(ii) Automatic (machine or
mechanized) arc welding and cutting - 100 volts.
(C) Special processes. When special welding
and cutting processes require higher open circuit voltages than those above,
there must be a way to prevent the operator from making accidental contact with
the high voltage.
(4) Installation of arc welding equipment.
(a) General. Installation including power
supply must be according to the requirements of subdivision 4/S.
(b) Grounding. Ground the frame or case of
the welding machine (except engine-driven machines) according to subdivision
4/S.
(5) Operation and
maintenance.
(a) Machine hook up. Before
starting operations check all connections to the machine to make certain they
are properly made. The work lead must be firmly attached to the work; magnetic
work clamps must be free from adherent metal particles of spatter on contact
surfaces. Coiled welding cable must be spread out before use to avoid serious
overheating and damage to insulation.
(b) Grounding. Check the grounding of the
welding machine frame. Give special attention to safety ground connections of
portable machines.
(c)
Manufacturers' instructions. Follow the printed rules and instructions supplied
by the manufacturers.
(d) Electrode
holders. When not in use place electrode holders so they cannot make electrical
contact with persons, conducting objects, fuel or compressed gas
tanks.
(e) Electric shock. Do not
use cables with splices within 10 feet (3 m) of the holder.
(f) Damage. Do not use work lead cables or
electrode lead cables with damaged insulation or exposed conductors.
(g) Cable. Do not coil or loop the electrode
cable around your body.
Notes
Publications: The publication(s) referred to or incorporated by reference in this rule are available from the agency.
Stat. Auth.: ORS 654.025(2) & ORS 656.726(3)
Stats. Implemented: ORS 654.001 - ORS 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.