Or. Admin. Code § 437-004-3650 - Roll-Over Protective Structures - Industrial Vehicles
(1) Application. There must be roll-over
protective structures (ROPS) on certain industrial vehicles manufactured after
July 1, 1969. ROPS requirements apply to the following types of industrial
vehicles and equipment: Rubber-tired self-propelled scrapers; front-end loaders
and dozers; wheel-type industrial tractors; crawler tractors; crawler-type
loaders; and motor graders, with or without attachments. This requirement does
not apply to sideboom pipe laying tractors, or other vehicles whose structure
prevents overturn. 4/U, OAR
437-004-3600 covers ROPS for
tractors used only in farming.
(2)
ROPS - general requirements.
(a) Roll-over
protective structures and their supporting attachments to industrial vehicles
must be capable of supporting twice the weight of the vehicle, applied at the
point of impact.
(b) The design
objective for roll-over protective structures on industrial vehicles is to
minimize the likelihood of a complete vehicle overturn, and to minimize the
possibility of the operator being crushed.
(c) There must be a vertical clearance of at
least 52 inches between the work deck and the ROPS canopy.
(d) Once removed, remount ROPS with bolts or
welding or equal or better quality as required for the original
mounting.
(3) Defects.
(a) Repairs to defective ROPS must be of
equal quality or better materials and welding as on the original
structure.
(b) Minimum performance
criteria for roll-over protective structures for designated vehicles are in the
following Society of Automotive Engineers (SAE) standards:
(A) Prime movers, for scrapers, water wagons,
bottom dump wagons, side dump wagons, rear dump wagons, towed fifth wheel
attachments. (SAE J1040, 1994)
(B)
Wheeled front-end loaders and wheeled dozers. (SAE J1040, 1994)
(C) Track-type tractors and front-end
loaders. (SAE J1040, 1994)
(D)
Motor graders. (SAE J1040, 1994)
(E) Wheel-type agricultural and industrial
tractors. (SAE J167, 1992)
(F)
Falling object protective structures (FOPS). (SAE J231, May 1981)
(4) Identification of
ROPS. Each ROPS must have the following information permanently affixed to the
structure:
(a) Manufacturer or fabricator's
name and address;
(b) ROPS model
number, if any; and
(c) Machine
make, model, or series number that the structure fits.
(5) Approved structures. Any machine in use,
with roll-over protective structures, complies with these rules if it meets the
roll-over protective structure requirements of the U. S. Army Corps of
Engineers, or the Bureau of Reclamation of the U. S. Department of the
Interior, in effect on April 5, 1972. The requirements in effect are:
(a)U. S. Army Corps of Engineers: General
Safety Requirements, EM-385-1-1 (September 1996).
(b) Bureau of Reclamation, U. S. Department
of the Interior: Safety and Health Regulations for Construction, Part II
(September 1971).