Or. Admin. Code § 629-043-0025 - Fire Tools and Fire Extinguishers
Pursuant to ORS 477.655, during fire season inside or within one-eighth of one mile of a forest protection district, operators must comply with the following minimum fire tool and fire extinguisher requirements:
(1) During
an operation in progress, provide at the operation area, or at a location
approved by the forester, a tool box that contains a number of firefighting
tools equal to or greater than the number of persons working on the operation.
(a) The tool boxes must be clearly identified
as containing fire tools;
(b) The
tools must only be used for fighting fire.
(c) The tools must include a mix of scraping
tools (such as pulaski or hazel hoe), cutting tools (such as pulaski or axe)
and shovels; appropriate for building a fire line and throwing dirt.
(d) The above requirements for a tool box and
tools to be used exclusively for fire-fighting do not apply if there are four
or fewer persons working on the operation and each person has a shovel,
suitable for fire-fighting, available for immediate use while working on the
operation.
(2) Provide
at each internal combustion engine, except power saws, one 2 A:10 BC or higher
(5 pound) rated fire extinguisher, or a combination of fire extinguishers that
provide equivalent protection approved by a nationally recognized testing
laboratory.
(3) Provide on each
truck:
(a) One 2 A:10 BC or higher (5 pound)
rated fire extinguisher, or a combination of fire extinguishers that provide
equivalent protection approved by a nationally recognized testing laboratory.
(b) One round pointed shovel which
has a face not less than 8 inches wide and a handle not less than 26 inches
long; and
(c) One pulaski or axe
which has a handle not less than 26 inches long.
(4) Provide at each block, except those
blocks located at a landing:
(a) One pump
equipped can or bladder containing not less than five gallons of water; and
(b) One round pointed shovel which
has a face not less than 8 inches wide and a handle not less than 26 inches
long.
(5) All bladders,
cans, pumps, tool boxes, tools and fire extinguishers referred to in this rule
must be kept ready for immediate use.
(6) Fire extinguishers required by this rule
must be equipped with a reliable and easily read pressure gauge or device or
method for measurement of the contents of the extinguisher.
(7) When an additional internal combustion
engine is permanently attached to a truck or other piece of power driven
machinery, one fire extinguisher for the combined engines, which complies with
section (2) of this rule, is sufficient.
(8) The forester may, in written order,
modify, reduce or waive any requirement of this rule if, in the judgment of the
forester, conditions so warrant or to take advantage of alternate methods or
equipment proposed by the operator which, in the judgment of the forester, will
provide equal or better suppression of fire.