Or. Admin. Code § 635-049-0290 - Fencing Standards for Cervid Propagation License-Type 2
All cervid propagation facility fences must be built and maintained in such manner as to make every reasonable effort to avoid escape by captive cervids.
(1) Conventional
perimeter fences must be, at a minimum, six feet above ground level for their
entire length. The bottom four feet must be woven wire mesh with 6-inch
vertical spacing and graduated horizontal spacing from 3-inch at the bottom to
8-inch at the top; constructed with either hinge or knotted joints; and at
least 12-1/2 gauge woven wire, 12-1/2 gauge high-tensile woven wire, or
nonclimbable chain link. If woven wire is used to attain the full six feet in
height by overlapping, it must be overlapped one row and securely fastened at
every other vertical row or woven together with cable. If supplemental wire is
used to attain a height of six feet, it may be smooth, barbed, or woven wire
(at least 12-1/2 gauge) with strands spaced not more than six inches
apart.
(2) Electric fencing
materials may be used on perimeter fences only to supplement conventional
fencing materials.
(3) All gates in
the perimeter fence must be constructed of a material that will meet or exceed
the strength of the fence, and must be equipped with two latching
devices.
(4) Posts used in the
perimeter fence must be:
(a) Of material of
sufficient strength to keep captive wildlife securely contained. Wooden corner
posts shall be a minimum of five inches in diameter at the small end and line
posts must be a wooden post with a minimum of four inches in diameter on the
small end, or a metal "T" post weighing at least 1.25 pounds per
foot;
(b) Extended at least six
feet above ground level and at least two feet below ground surface;
(c) Spaced no more than 10 to 15 feet apart
on medium tensile woven wire, 15 to 20 feet on high tensile woven wire, and 10
feet apart on metal "T" posts. If conditions warrant, stays or supports between
posts may be required; and
(d)
Braced with wood or with suitable metal material properly set at all
corners.
(5) Cervid-proof
swinging water gaps and stream crossings supported with steel cables and
constructed to equal or exceed the standards of the fence are required. These
crossings are subject to individual approval by department inspection. If, in
the judgment of the department inspector, the crossings are inadequate to
prevent ingress and egress during high water, the facility shall not pass
inspection, and no cervids shall be held therein.
(6) Existing Facilities: Any deviation from
these standards must first be submitted in writing to the department and
approved by the director. This does not apply to repairs of existing facilities
as long as the repairs maintain existing standards.
(7) New Facilities or Expansion of Existing
Facilities: Approval of deviations from these standards must be granted by the
director prior to construction. The facility shall not be occupied without
prior department inspection or approval.
Notes
Stat. Auth.: ORS 496.012, 496.138, 497.308, 497.318, 498.002 & 498.052
Stats. Implemented: ORS 496.012, 496.138, 497.308, 497.318, 498.002 & 498.052
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.