Or. Admin. Code § 690-210-0250 - Top Terminal Height
(1) The
casing head or pitless unit of any well shall extend a minimum of 12 inches
above the finished ground surface or pumphouse floor, and a minimum of 12
inches above the local surface runoff level. The ground surface immediately
surrounding the top of the well casing or pitless unit should be graded so as
to drain surface water away from the well. Without permission of the Director,
no casing shall be cut off below land surface except to install a pitless unit
or during permanent abandonment of a well.
(2) Application to the Director to reduce the
top terminal height of casing shall include:
(a) A description of physical characteristics
of the well site which make the requested change necessary; and
(b) A description of additional steps to be
taken over and above the minimum standards in these rules which will assure
adequate protection of the ground water resource.
(3) The Director may approve a reduction of
the top terminal height of the casing only upon a determination that the
additional precautions to be taken and specific physical characteristics of the
site would prevent contamination of the ground water resource.