Or. Admin. Code § 690-210-0290 - Liner Pipe

Liner pipe installed through caving formations and installed without driving, may be of lighter weight than specified by Table 210-2 under OAR 690-210-0190. Such lightweight pipe shall have a wall thickness equal to or greater than 0.188 inch. All liner pipe shall be of steel, in new or like new condition, being free of pits or breaks; or shall be of polymerized vinyl chloride (PVC) type 1220 or 1120 and SDR 26 (Class 160) or greater wall thickness. Liner pipe installed in a well shall extend or telescope at least eight feet into the lower end of the well casing. In the event that more than one string of liner pipe is installed, each string shall extend or telescope at least eight feet into the adjacent larger diameter liner pipe. Liner pipe shall be removable. Liner pipe may be welded or hooked onto the permanent well casing but shall not be permanently fixed to a well casing or borehole wall using packers or grout which would prohibit the liner's removal. (See Inner Casing, OAR 690-210-0230.)

Notes

Or. Admin. Code § 690-210-0290
WRD 9-1978, f. 12-12-78, ef. 1-1-79; WRD 13-1986, f. 10-7-86, ef. 11-1-86, Renumbered from 690-061-0011; WRD 7-1988, f. & cert. ef. 6-29-88; WRD 8-1993, f. 12-14-93, cert. ef. 1-1-94; WRD 7-2001, f. & cert. ef. 11-15-01; WRD 5-2023, amend filed 06/22/2023, effective 7/1/2023

To view attachments referenced in rule text, click here to view rule.

Statutory/Other Authority: ORS 536.090, ORS 537.505-537.795, ORS 536.027, ORS 536.900 & ORS 537.992

Statutes/Other Implemented: ORS 536.090, ORS 537.505-537.795, ORS 536.900 & ORS 537.992

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.