Or. Admin. Code § 690-210-0420 - Surface Curbing
(1) The surface
curbing required in OAR 690-210-0400 shall be of concrete, concrete tile, or
steel. If concrete is used, the concrete wall thickness shall not be less than
six inches. In the case of buried slab type wells, well casing meeting the
minimum specifications given in 690-210-0190 through 690-210-0220 shall be
used. (See Figure 210-13.)
(2) If
precast concrete tile or steel casing is used for the surface curbing, the well
diameter to the bottom of the surface curbing shall be eight inches greater
than the outside diameter of the tile or steel, and the annular space shall be
completely filled with grout in accordance with OAR 690-210-0310 through
690-210-0340. (See Figure 210-13).