Or. Admin. Code § 690-220-0040 - Abandonment of Cased Wells
(1) If all or a
portion of the water supply well casing or the liner pipe is not removed during
the abandonment of a well, the remaining casing or liner shall be thoroughly
ripped or perforated. The number and size of perforations may vary, however,
the perforations must be sufficient enough to allow grout to migrate outside
the casing and effectively prevent the vertical movement of water. The annular
space between the casing or liner and the drillhole wall shall be effectively
and completely filled with cement grout applied under pressure.
(2) Perforations are not required in the
sealed interval provided proof of the original seal can be verified with the
original well report. The verified seal interval shall be filled with cement
grout, concrete or unhydrated bentonite.
(3) Uncased portions of a cased well to be
abandoned shall be filled in accordance with OAR 690-220-0030 through
690-220-0050.
(4) The well casing
to be abandoned may be severed below land surface and removed. (See Figure
220-3.)
Notes
To view attachments referenced in rule text, click here to view rule.
Statutory/Other Authority: ORS 536.090 & 537.505 - 537.795
Statutes/Other Implemented: ORS 536.090 & 537.505 - 537.795
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.