Or. Admin. Code § 813-310-0050 - Visitable Interior Route and Doorway Requirements

(1) Hallways along a visitable route shall have a minimum clearance of 36 inches, and doorways along that route shall have a minimum clearance of 32 inches.
(2) The maximum threshold height for visitable interior doors shall be 1/2 inch. The threshold shall be beveled down to the adjacent surface at a slope not steeper than 1:2.
(3) The visitable powder room doorway shall have either an exterior swing door, a pocket door, or an interior swing door. An exterior swing door shall not block access along the visitable interior route, in the Department's determination. An interior swing door shall not block the reasonable use of the fixtures in the powder room, in the Department's determination.

Notes

Or. Admin. Code § 813-310-0050
OHCS 3-2004, f. & cert. ef. 6-28-04

Stat. Auth.: ORS 183 & 456.514

Stats. Implemented: ORS 456.506 - 456.514

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.