Or. Admin. Code § 837-110-0020 - Firefighting Water Supplies
(1) When
burning acreage, the following firefighting vehicles shall be provided:
(a) Up to 50 acres -- At least two water tank
vehicles with a minimum of 1,000 gallon water capacity shall be on
site;
(b) 50 to 200 acres -- At
least three water tank vehicles with a minimum of 1,500 gallon water capacity
shall be on site;
(c) Over 200
acres -- At least four water tank vehicles with a minimum of 3000 gallon water
capacity shall be on site.
(2) Refill Requirements: During actual
firefighting operations the water requirements described in this section shall
be maintained at or above 25 percent of the specified amount. Within the buffer
zone described in OAR 837-110-0080, this requirement shall be raised to at
least 50 percent.
NOTE: Vehicles with smaller capacity water tanks may be used to meet the total gallonage capacity required by subsections (1)(a) through (c) of this rule.
Notes
Stat. Auth.: ORS 476.030, ORS 476.380 & ORS 478.960
Stats. Implemented: ORS 476.380 & ORS 478.960