17 Pa. Code § 43.1 - Technical specifications and requirements for spark arrestors
When locomotives are operating through forest lands in the Commonwealth between March 1 and November 15 of each year they shall be equipped with spark arrestors of the following efficiency standards:
(1) Spark arrestors shall be at least 80%
efficient in the retention or destruction of carbon particles .023 inches in
diameter and larger for 30-100% of the locomotive engine's exhaust flow rate.
The total manifold exhaust leg back pressure may not exceed 3 1/2 inches of
mercury.
(2) Each spark arrestor
model shall have certification that it meets the requirements of the
Association of American Railroads and documentation from the United States
Forest Service that the spark arrestor model has been tested and approved for
use. This certification and documentation will be provided to the Bureau of
Forestry before the arrestor model is installed. Turbo-charged locomotives
properly equipped and maintained are not included within this
regulation.
Notes
This section cited in 17 Pa. Code § 43.3 (relating to installation schedule).