25 Pa. Code § 129.17 - Kraft pulp mills
(a) A person
may not cause or permit the emission into the outdoor atmosphere of total
reduced sulfur from kraft pulp mills in excess of the quantities in the
following table:
| PPM (VOLUME) DRY | CONDITION | |
| Recovery furnace-old design (without welded wall or membrane wall construction or emission-control designed air systems) | 20 | 12 hour average-correctedto 8% oxygen by volume. |
| Recovery furnace-new design (with both welded wall ormembrane wall constructionor emission-control designedair systems) | 5 | 12 hour average-correctedto 8% oxygen by volume. |
| Lime kiln (a rotary or fluosolidunit used to calcine calciumcarbonate into calcium oxide) | 20 | Never to be exceeded-corrected to 10% oxygen by volume. |
| Digester systems (continuous orbatch process for cooking woodchips in sodium hydroxide andsodium sulfide to producecellulosic material) | 5 | Never to be exceeded. |
| Multiple effect evaporator system (vapor heads, heating elements,hot wells, condensers andassociated equipment used toconcentrate spent pulp mill cooking liquid) | 5 | Never to be exceeded. |
| Smelt dissolving tank (the vesselused to produce an aqueoussolution from the molten mixturedischarged from the floor of arecovery furnace) | 20 | Never to be exceeded. |
(b) Total reduced sulfur emissions shall be
monitored continuously at recovery furnaces, digester systems and multiple
effect evaporator systems unless emissions are incinerated at 1,200°F for
.5 seconds or incinerated to provide equivalent total reduced sulfur control.
(1) Monitors, installation, operation,
maintenance and reporting shall be as prescribed in Chapter 139 (relating to
sampling and testing).
(2) TRS
monitoring systems installed under this section shall meet the minimum data
availability requirements in Chapter 139 Subchapter C (relating to requirements
for source monitoring for stationary sources).
(3) The Department may use the data from the
monitoring systems or from an alternate monitoring system to determine
compliance with subsection (a).
(4)
Source owners and operators shall achieve compliance with these monitoring
provisions by May 7, 1991.
(c) Compliance with subsection (a) shall be
achieved in accordance with the following schedule:
| ACTIVITY | MONTHS AFTER MAY 7, 1988 | |
| EXISTING SOURCES | RECOVERY FURNACE (NEW SOURCE) | |
| Submit for Department approvala plan for achieving compliance | 6 | 6 |
| Submit for Department approvala plan of necessary equipment | 12 | 24 |
| Issue purchase orders | 24 | 36 |
| Achieve compliance | 36 | 72 |
Notes
The provisions of this § 129.17 issued under section 5 of the Air Pollution Control Act (35 P.S. § 4005).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.