25 Pa. Code § 139.18 - Calculation of alternative opacity limitations
(a) The results of opacity measurements
obtained by the technique specified in §
123.45 (relating to alternative
opacity limitations) for the entire time period from the beginning of the first
performance test to the end of the third performance test will be reduced to
1-minute averages.
(b) The 1-minute
averages which correspond to each of the three performance tests will be used
for calculation of the alternative opacity limits and treated as if they
represented contiguous data.
(c) The
highest 1-minute average as determined in subsection (b) is the alternative
opacity limitation not to be exceeded at any time.
(d) The median value of the 1-minute averages
as determined in subsection (b) is determined.
(e) One-minute averages equal to or less than
the median value calculated in subsection (d) will be eliminated from
calculations in subsections (f) and (g).
(f) The mean and modified 95% confidence
interval shall be calculated for the remaining 1-minute averages as follows:
Click to view image
Xi = individual 1-minute average
n = number of individual 1-minute average (after elimination of averages less than or equal to the median value)
C.I.m=modified 95% confidence interval
(g) The alternative
opacity limitation not to be exceeded more than 3 minutes in any 1 hour shall
be equal to the sum of the mean and the modified 95% confidence interval as
calculated in subsection (f) (X + C.I.m,truncated to an
integer % opacity.
(h) An hourly
average opacity limitation not to be exceeded at any time will be calculated as
follows:
(1) The 1-minute averages as
determined in subsection (b) will be grouped in discrete hourly time periods
starting with the beginning of the first performance test.
(2) A remaining 1-minute averages
constituting less than a full hourly time period will be eliminated from
calculations in paragraphs (3) and (4).
(3) The mean for each hourly time period will
be calculated as follows:
Click to view image
(4) The
hourly average opacity limitation not to be exceeded at any time shall be equal
to the highest mean as calculated in paragraph (3) truncated to the nearest
integer % opacity.
Notes
This section cited in 25 Pa. Code § 123.45 (relating to alternative opacity limitations).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.