34 Pa. Code § 29.134 - Construction of guards
(a)
Materials. Guards or enclosures shall be constructed of cast
iron, expanded metal, perforated or solid sheet metal, or wire mesh on a frame
of angle iron or iron pipe securely fastened to the floor or to the frame of
the machine. Existing guards may be allowed to remain in position if, in the
judgment of the Department, they afford adequate protection.
(b)
Burrs. Metal shall be
free from burrs and sharp edges.
(c)
Wire mesh. Wire mesh
shall be of the type in which the wires are securely fastened at each cross
point either by welding, soldering, or galvanizing, except in case of diamond
or square wire mesh made of No. 14 gauge wire, 3/4 inch mesh or
heavier.
(d)
Uprights.
The uprights used for supports shall be of angle iron one inch by one
inch by 1/8 inch to 1 1/2 inches by 1 1/2 inches by 3/16 inch; iron pipe 3/4
inch to 1 1/2 inches inside diameter, or construction of equivalent strength.
The sizes may vary between the above limits according to the weight and size of
the guards and their location in respect to aisles and the possibility of being
damaged by moving equipment. There shall be no unsupported panels of guards of
greater dimensions than 42 inches.
(e)
Filling material. The
filling material between the supports of a guard shall be as follows:
Click to view image
(f)
Fastening. The filling materials shall be fastened to the
supports by one of the following methods:
(1)
Angle iron supports. By means of 3/4 inch by 1/8 inch flat
iron fastened to the angle by means of 3/16 inch bolts or rivets, placed at
intervals not exceeding ten inches, or by wooden strips one inch by one inch
fastened to the angles by means of 3/16 inch bolts; or by other methods
providing equivalent strength. Perforated or sheet metal shall be either bolted
or riveted directly to the angle, or spot welded.
(2)
Piping. Piping shall be
clamped.
(g)
Standard railing. When railings are used for the guarding of
machinery, there shall be compliance with the following requirements:
(1) Railings shall be not less than 42 inches
in height provided with an intermediate rail between the toprail and the floor,
and shall be constructed in a permanent and substantial manner, smooth and free
from protruding nails, bolts and splinters.
(2) If constructed of pipe, they shall be not
less than 1/4 inches inside diameter.
(3) If constructed of structural metal bars,
they shall be the equivalent of 1 1/2 inches by 1 1/2 inches by 3/16 inch
angles.
(4) If constructed of wood,
the posts shall be not less than 2 inches by 4 inches or the equivalent.
Toprailings shall be not less than 2 inches by 4 inches or 1 inch by 4 inches
if another board of not less than 1 inch by 4 inches is securely nailed to the
sides of the posts and to the toprail. Center railings shall be not less than 1
inch by 4 inches.
(5) Posts and
uprights shall be spaced not more than 8 feet apart.
(6) The rails, when of metal shapes, metal
bars or wood, shall be placed on that side of the posts which afford the
greater support and protection.
(7)
When panels are fitted with substantial expanded metal or wire mesh, the middle
rails may be omitted.
(8) Toeboards
shall be 6 inches or more in height of wood, metal or of metal grill not
exceeding one inch mesh. Toeboards at flywheel pits should be placed as close
to the edge of the pit as possible.
(h)
Wood guards. Wood guards
may be used in chemical industries or in construction work when fumes or other
manufacturing conditions may cause rapid deterioration of metal guards. In all
other industries the use of wood guards is prohibited except by special
permission of the Board.