34 Pa. Code § 35.133 - Fire protection
The following recommendations apply to fire protection:
(1) Ducts longer than 10
feet should have clean-out doors at 10 foot intervals, or should be so
constructed as to be easily taken apart for cleaning.
(2) To minimize the spread of fire, finished
products should be removed immediately from the vicinity of the spray booths or
from the room booths, regardless of location.
(3) The surfaces of all booths, after they
have been made clean and free from accumulations of sprayed materials, should
be greased and papered, or otherwise prepared so that they may be easily
cleaned.
(4) Spraying operations
should be located under smooth ceilings.
(5) For the spraying of materials containing
volatile solvents, there should be a separate exhaust duct for each
booth.
(6) Where plants at present
have three or more booths connected to a single exhaust fan they should,
whenever possible, change equipment to conform to this subchapter.