34 Pa. Code § 39.88 - Floors, floor openings, passageways, stairs
(a) Floors shall have even surfaces and
afford secure footing. Projecting nails, loose boards, uneven or greasy wood
floors, and smooth iron floors shall be avoided.
(b) Passageways, stairways, and working
spaces shall be unobstructed, and shall, if possible, provide at least 6.5 feet
of headroom unless they are used solely for infrequent inspection, construction
and repair. Reference should also be made to §
39.104 (relating to working space
about electrical equipment).
(c)
Floor openings over 2 feet deep, and stairways or raised platforms over 4 feet
high shall be provided with suitable handrails. Except for loading platforms,
such rails are recommended if height exceeds 2 feet, especially where they are
adjacent to live or moving parts, or the working space on the platform is
restricted.
(d) Floor openings over
6 feet deep, and the edges of all raised platforms over 6 feet high, shall, if
possible, be provided with suitable toeboards.
(e) Toeboards shall, if possible, be arranged
at back of stairway treads if they are over exposed live or moving parts or
over working spaces, passageways or other stairways.