34 Pa. Code § 405.32 - Platforms
(a) A stage,
orchestra or organ console elevator platform shall be comprised of steel frame
construction and designed with a safety factor of at least six based on the
highest rating of either the rated lifting load or the rated static load
uniformly distributed.
(b) When the
travel of a stage, orchestra or organ console elevator extends above the top of
the shaftway enclosure, the platform shall be equipped with an apron at least
as deep as the space between the top of the shaftway enclosure and the
underside of the platform when the platform is at its limit of
travel.