34 Pa. Code § 43.15 - Hoisting ropes
(a) When the
hoisting or lowering of men is done by any means other than human or animal
power, the rope or cable used shall be composed of metal wires. The metal wires
may be laid around a hemp center.
(b) All ropes shall have a factor of safety
of at least eight. All cables shall have a factor of safety of at least
five.
(c) No head or angle sheave
of a diameter less than 40 times the diameter of the rope shall be used for
hoisting or lowering men.
(d) Ropes
or cables with any of the following characteristics shall not be used to hoist
or lower men:
(1) If the number of breaks in
any consecutive 10 feet of rope exceeds 10% of the total number of wires
composing the rope.
(2) If the
wires on the crown of the strands are worn down to less than 60% of their
original area.
(3) If there are
marked signs of corrosion.
(e) All ropes used for hoisting or lowering
men shall be thoroughly inspected once a week by some competent person
designated by the superintendent. Any rope or cable found to be below the
requirements set forth in this subchapter shall not be used to hoist or lower
men.
(f) Every rope used for
hoisting or lowering men shall be securely fastened at both ends, and when in
use shall never be fully unwound; at least two full turns shall remain always
on the drum or reel. The end of the rope attached to the conveyance in the
shaft shall be securely fastened within a tapered socket or shall be bound
around on an oval thimble and then fastened to itself by the use of three or
more approved clamps.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.