34 Pa. Code § 43.35 - Power wires and cables
(a) In all
shafts where the angle of inclination is above 45° from the horizontal, and
in all hoisting shafts or manway compartments, all power wires and cables shall
be amply protected by insulation and substantially fixed in position. All shaft
cable shall be supported on insulators that do not cause abrasion of the
covering or insulation, and shall be spaced so that no part of the cable is
under a tension greater than 1/4 its ultimate strength. The cable shall be held
in position at points between the insulators by grips or cleats that do not
cause abrasion of the covering or insulation. If the cables are not completely
boxed in and protected from falling material, space shall be left between them
and the side of the shaft so that they may yield and lessen a blow from falling
material. This requirement shall not be construed to prevent the installation
of efficiently insulated wires in metal conduit, to transmit power
underground.
(b) If it is not
possible to keep the cables or feed wires in tunnels at least 12 inches from
any part of the tunnel, car or locomotive, they shall be specially protected by
proper guards.