34 Pa. Code § 43.90 - Blasting
(a) There shall be
one blaster in charge of each section. No one who has not received a permit
from the Department shall be employed as a blaster anywhere within the
jurisdiction of the Department.
(b)
When firing by electricity from power or light wires, a proper switch shall be
furnished with the lever in a down position when "off." The switch shall be
fixed in a locked box to which no person shall have access except the blaster.
There shall be provided flexible leads or connecting wires not less than 5 feet
in length with one end attached to the incoming lines and the other end
provided with plugs that shall be connected to an effective ground. After
blasting, the switch lever shall be pulled out, the wires disconnected and the
box locked before any person shall be allowed to return, and shall remain so
locked until again ready to blast.
(c) All electric light wires in the working
chamber shall be provided with a disconnecting switch, which shall be thrown to
disconnect all current from the wires in the working chamber before electric
light wires are removed or the charge exploded.
(d) Before he sets off the blast, the blaster
shall cause a sufficient warning to be sounded and shall be responsible that
all persons retreat to safe shelter, and shall also see that they do not return
until he reports it safe for them. He shall report to the foreman and furnish
names of all persons refusing to obey his caution.