34 Pa. Code § 47.169 - Brass foundries
(a)
Generally. The regulations relating to dust, smoke, gases,
fumes, ventilation, sanitation, heat, light, gangways, aisles, safety
appliances, washrooms, cleaning rooms, drying and locker accommodations, as
specified for iron and steel foundries, shall apply to brass foundries, except
that main gangways shall be not less than 4 feet wide and gangways between
molds on spill troughs not less than 3 feet wide.
(b)
Platform. When the crown
plate of an upright melting furnace is elevated above the surrounding floor in
excess of 12 inches, the furnace shall be equipped with a platform guarded with
a standard railing. The platform shall be constructed of metal or other
fire-resistive material, extend along the front and sides of the furnace flush
with the crown plate, be at least 4 feet in width, and be clear of all
obstructions during pouring time. If the platform is elevated above the floor
in excess of 12 inches, the lowering from the platform of crucibles containing
molten metal shall be by mechanical means.
(c)
Crucibles. When the
combined weight of a crucible, tongs and molten metal exceeds 100 pounds, it
shall be removed from the furnace and deposited on the floor by mechanical
means.
(d)
Smoke boxes.
When smoke finish is desired on molds made on benches or tubs, smoke
boxes which shall effectively trap the smoke shall be used and connected with
flues to the outer air.
(e)
Molders. When molders work side by side, at least 5 feet of
space sideways shall be allowed for each employe, and a clear space of 3 feet
shall be provided back of each employe.
(f)
Ventilators. Hoods shall
be provided directly above all brass melting furnaces using gas or oil as fuel,
which effectively trap all gases and fumes generated in the melting of the
metal. The hoods shall be provided with outlet pipes to lead the gases or fumes
to the outer air. Ventilators shall be provided over all other furnaces used
for melting brass or composition metal to effectively remove the gases above
the furnaces.
(g)
Light. Brass foundries shall be provided with natural light
from at least two sides, or from at least one side with skylights in the
roof.
(h)
Legs and feet.
Persons removing or handling pots containing molten metal from
furnaces shall be provided with protection for the legs and feet.
(i)
Dirt riddling. Gangway
dirt and floor scrapings shall not be riddled in the room where workmen are
employed, unless it is dampened so as to prevent the rising of dust.
(j)
Stoves. When stoves for
drying molds are located in the rooms used by workmen they shall be surrounded
by a casing of fire-resistive material to the full height of the
stove.
(k)
Ceiling.
No brass foundry shall be constructed after November 1, 1915, with a
clearance less than 14 feet between the lowest point of the ceiling and the
floor, except that where a peak, saw-tooth, monitor or arch roof is
constructed, the side walls may be of a minimum height of 12 feet.