34 Pa. Code § 5.38 - Catch platforms
(a) During
the demolition of the exterior walls of a structure originally more than 70
feet high, catch platforms shall be erected along the exterior faces of such
walls where necessary to prevent injury to the public or workmen
below.
(b) Such catch platforms
shall be constructed and maintained not more than three stories below the story
from which the exterior walls are being removed. Where demolition has
progressed to within three stories of ground level, catch platforms are no
longer required.
(c) Catch
platforms shall be not less than 5 feet in width, measured in a horizontal
direction from the face of the structure, and shall consist of outriggers and
planks. Planks shall be laid tightly together, without openings between them
and the wall.
(d) Catch platforms
may be constructed of material other than wood, if such material is of equal
strength and does not otherwise lessen the security against falling
material.
(e) Catch platforms shall
be capable of sustaining a live load of not less than 125 pounds per square
foot.
(f) Catch platforms shall be
so inclined that the outer edge is at least 10 inches higher than the inner
edge.
(g) Supports shall consist of
outriggers of ample strength, secured against turning and spaced not more than
10 feet apart.
(h) Each outrigger
shall have ample support against the building or in window openings and shall
be adequately secured. Planks supported by the outrigger shall be not less than
2 inches thick and the ends shall overlap each other for a distance of at least
1 foot over the supports. All planks shall be secured against
displacement.
(i) The outer edge of
each catch platform shall be provided with a substantial enclosure, constructed
at an angle of approximately 45° with the horizontal and having its outer
edge not less than 48 inches from the platform, measured along the slope of the
enclosure.
(j) The enclosure wall
shall consist of boards nailed closely together. Such enclosure shall be
secured to supports placed not more than 10 feet apart.
(k) There shall be no openings between the
platform and the enclosure.
(l)
Supports for the enclosure shall be not less than 2 by 6 inches, in sections
with the greater dimension at right angles to the enclosures.
(m) Materials shall not be dumped on catch
platforms, nor shall such platforms be used for the storage of
materials.