34 Pa. Code § 53.11 - Story height

A-3 occupancies shall be governed by the story height limitations in the following table:

Construction Type Maximum Story Height
Fireresistive No Limit
Noncombustible 3 Stories*
Protected Heavy Timber 2 Stories*
Ordinary 2 Stories*
Wood Frame 1 Story*
(b) *An additional story shall be permitted in noncombustible, protected heavy timber, ordinary or wood frame construction when the building is 1-hour rated construction or totally protected by an automatic sprinkler system. The maximum story height may be increased by two stories when both 1-hour rated construction and total automatic sprinkler protection are provided.
(c) Noncombustible, protected heavy timber, ordinary and wood frame construction types shall be considered 1-hour rated construction when bearing walls, columns, beams, other supporting members, ceiling/roof assemblies, floor/ceiling assemblies, stairways, and other openings through floors are of 1-hour rated construction.

Notes

34 Pa. Code § 53.11

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.