34 Pa. Code § 53.11 - Story height
A-3 occupancies shall be governed by the story height limitations in the following table:
| Construction Type | Maximum Story Height |
| Fireresistive | No Limit |
| Noncombustible | 3 Stories* |
| Protected Heavy Timber | 2 Stories* |
| Ordinary | 2 Stories* |
| Wood Frame | 1 Story* |
(b) *An
additional story shall be permitted in noncombustible, protected heavy timber,
ordinary or wood frame construction when the building is 1-hour rated
construction or totally protected by an automatic sprinkler system. The maximum
story height may be increased by two stories when both 1-hour rated
construction and total automatic sprinkler protection are provided.
(c) Noncombustible, protected heavy timber,
ordinary and wood frame construction types shall be considered 1-hour rated
construction when bearing walls, columns, beams, other supporting members,
ceiling/roof assemblies, floor/ceiling assemblies, stairways, and other
openings through floors are of 1-hour rated construction.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.