34 Pa. Code § 55.21 - Minimum exits
(a) There shall
be a minimum of two exits reasonably remote from each other. At least 50% of
required exits shall be exit discharge doors, stair towers or ramps.
(b) Basements used only for storage or
mechanical equipment without any permanent occupancy shall have a minimum of
two exit access paths except that the Department may permit a single exit
access for basements used only for storage or mechanical equipment without any
permanent occupancy of less than 1,000 square feet.
(c) Mezzanine levels shall have a minimum of
two exit access paths except that the Department may permit a single exit
access from mezzanines less than 1,000 square feet or mezzanines used
exclusively for storage or mechanical equipment without a permanent
occupancy.
(d) An individual
apartment which occupies more than one floor level shall only be required to
have an exit from one floor level.