34 Pa. Code § 6.31 - Cables, ropes, block, and tackle
(a)
Cables. Cables for scaffolds and hoists shall not be less
than 1/4 inch in diameter, and shall possess a factor of safety of at least
eight. A metal tag shall be placed on all cables at a point readily accessible
to inspection showing the size and material of the cable, including the maximum
safe load and the date of renewal. There shall be compliance with the following
additional requirements:
(1)
Cable
fastenings. The fastenings of all cables shall be of an approved
type. Particular care shall be taken in the pouring of sockets, and the metal
used shall be zinc. Where thimbles and clamps are used the fastenings shall be
made under the supervision of a competent man and not less than three approved
clamps or clips shall be used at each fastening. Clamps shall be installed with
the U-bolt on the dead end of the cable.
(2)
Splicing. The splicing
of cables is prohibited.
(3)
Maintenance and inspection. Cables shall at all times be
maintained in a perfectly safe operating condition and frequent inspections
shall be made.
(4)
Riding
of cables. Where "riding" of the cable on the drum occurs, it shall be
adjusted immediately but the adjustment shall only be done by someone
thoroughly familiar with the machine and experienced in such
work.
(b)
Ropes. For all other lifeline applications, rope of a minimum
of 3/4 inch manila or equivalent, with a minimum breaking strength of 5,400
pounds, shall be used. A tag shall be placed on all ropes readily accessible to
inspection, showing the size and material of the rope, including the minimum
breaking strength in pounds. In addition, the following requirements shall be
met:
(1)
Fastenings of
ropes. Ropes shall be at least double lashed at each point of
suspension. Lifelines used on rockscaling operations, or cut in areas where the
lifeline may be subjected to cutting or abrasion, shall be a minimum of 7/8
inch wire core manila rope.
(2)
Splicing. The splicing of ropes is prohibited.
(3)
Knots. Rope knots shall
have their free ends lashed to the standing part to prevent their becoming
untied. All knots shall be tested and made secure before the rope is
used.
(c)
Block
and tackle. Block and tackle shall fit the size of the rope they carry
and shall be so constructed that they do not chafe or abrade the ropes running
through them.
(d)
Inspection and storage. All ropes, slings, and tackle shall be
thoroughly and frequently inspected. When not in use they shall be stored in a
dry place.
(e)
Protection
of rope or cable when using acid. Wherever any solution containing
acid, caustic or any other substance injurious to hemp rope fibre or iron or
steel cables is to be used to clean buildings or other structures, the hangers
and falls of the scaffold shall be protected to a height of at least six feet
above the platform with acid-resisting material, and further provided that the
ropes or cables shall hang over the outside edge of the scaffold platform.
Solutions containing acid or caustics shall not be stored in the same room with
scaffolding equipment.
(f)
Builders' hoists. Builders' hoists shall comply with all the
requirements of Chapter 7 (relating to elevators, lifts, escalators,
dumbwaiters, hoists, and tramways), and shall not be operated without a "State
Certificate of Operation" on display in or adjacent to the hoist
shaftway.
Notes
This section cited in 34 Pa. Code § 6.14 (relating to suspended scaffolds); 34 Pa. Code § 6.15 (relating to painters' swinging scaffolds); 34 Pa. Code § 6.19 (relating to needle beam scaffolds); 34 Pa. Code § 6.20 (relating to roofing brackets and scaffolds); and 34 Pa. Code § 6.26 (relating to boatswain's chair).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.