34 Pa. Code § 7.111 - Shaftway construction
(a) The
shaftways of orchestra and organ console elevators shall be of fire-resistive
construction below the top landing. The inside surface of such shaftways,
within the limits of travel, shall have a smooth finish without any projections
or recesses except for landing entrances, guides and guide brackets, vertical
slots when required for concealed guides, and junction boxes and conduits for
wiring. Projections or recesses at landing entrances shall be beveled on the
underside or guarded with metal plates. The angle of such bevels or guard
plates shall not be less than 60° from the horizontal.
(b) The shaftways of lumber elevators shall
be enclosed on all sides not used for loading or unloading with solid
partitions not less than 6 feet in height and shall be flush. All points of
loading and unloading shall be protected by movable bars or railings. Gates, as
specified in §
7.278(c)
(relating to landing gates) are required where the travel exceeds 6 feet and
there are two or more landings. All shearing points shall be protected by
flaring at an angle of not less than 60° from the horizontal.
(c) A pit shall be provided at the bottom of
every shaftway of such depth that when the platform is at its lowest limit of
travel the distance between the lowest point of the underside of the platform
framing and to the floor of the pit shall not be less than 2 feet.
(d) The bottom landing openings of orchestra
and organ console shaftways shall be protected by sliding doors of
fire-resistive construction. If swinging doors are used they shall open
outward.
(e) Railings and toeboards
shall be provided at the floor levels of orchestra and organ console
elevators.
(f) Steel rails shall be
used for guides of stage, orchestra, and organ console elevators. Lumber
elevators shall be provided with substantial guides of either wood or
steel.
(g) Shaftway landing doors
shall be equipped with approved locking devices.