34 Pa. Code § 7.361 - General requirements
(a) The
employer shall comply with the manufacturer's specifications and limitations
applicable to the operation of all hoists and elevators. If manufacturer's
specifications are not available, the limitations assigned to the equipment
shall be based on the determination of an approved Certified State Commissioned
Inspector competent in the field.
(b) Rated load capacities, recommended
operating speeds, and special hazard warnings or instructions shall be posted
on cars and platforms.
(c) Wire
rope shall be removed from service when any of the following conditions exists:
(1) In hoisting ropes, six randomly
distributed broken wires in one rope lay or three broken wires in one strand in
one rope lay.
(2) Abrasion,
scrubbing, flattening, or peening, causing loss of more than 1/3 of the
original diameter of the outside wires.
(3) Evidence of any heat damage resulting
from a torch or any damage caused by contact with electrical wires.
(4) Reduction from nominal diameter of more
than 3/64 inch for diameters up to and including 3/4 inch; 1/16 inch for
diamerers 7/8 to 1 1/8 inches; and 3/32 inch for diameters 1 1/4 to 1 1/2
inches.
(d) Hoisting
ropes shall be installed in accordance with the wire rope manufacturer's
recommendations.
(e) The
installation of live booms on hoists is prohibited.
(f) The use of endless belt-type man lifts on
construction shall be prohibited.