34 Pa. Code § 7.371 - Hoist towers
(a) Hoist
towers outside the structure shall be enclosed for the full height on the side
or sides used for entrance and exit to the structure. At the lowest landing,
the enclosure on the sides not used for exit or entrance to the structure shall
be enclosed to a height of at least 10 feet. Other sides of the tower adjacent
to floors or scaffold platforms shall be enclosed to a height of 10 feet above
the level of such floors or scaffolds.
(b) For towers located outside a building,
the enclosures, except those at the lowest landing, may be omitted on the sides
where there is no floor or scaffold adjacent to the hoistway. Enclosures on the
entrance and exit side of the hoistway shall be full height. Other enclosures,
where required, shall be not less than 10 feet high.
(c) Towers inside of structures shall be
enclosed on all four sides throughout the full height.
(d) Towers shall be anchored to the structure
at intervals not exceeding 25 feet. In addition to tie-ins, a series of guys
shall be installed. Where tie-ins are not practical the tower shall be anchored
by means of guys made of wire rope at least 1/2 inch in diameter, securely
fastened to anchorages to ensure stability.