52 Pa. Code § 33.122 - Side clearances
(a) Minimum
side clearances from center line of tangent railroad tracks, used or proposed
to be used for transporting freight cars, shall conform with the regulations of
this section, except that structures, including platforms and tracks,
constructed or under construction prior to the adoption of this Subchapter may
be maintained and extended at existing clearances.
(b) All structures and obstructions above the
top of the rail, except those specifically exempted in this section, shall have
a minimum side clearance of 12 feet from the center line of the
track.
(c) Platforms, except
platforms adjacent to main or passing tracks, 4 feet or less above the top of
the rail may have lesser clearance than 8 feet, 6 inches, from center line of
tracks on one side of such tracks only if a full clearance of 8 feet, 6 inches,
is maintained on opposite side of track or track centers to adjacent track are
not less than 14 feet.
(d)
Platforms 4 feet, 6 inches, or less above the top of the rail, if used
principally for loading or unloading refrigerator cars, may be constructed 8
feet from the center line of the track.
(e) Platforms previously constructed at less
than the clearances prescribed in this section may be extended at such lesser
clearances, unless such an extension is in connection with reconstruction of
the original platform.
(f) Low
passenger platforms not over 8 inches above the top of the rail may be 5 feet,
1 inch, from the center line of the track. High passenger platforms not over 4
feet above the top of the rail may be 5 feet, 7 inches, from the center line of
the track.
(g) Side clearances,
other than for platforms, on sidings only, at entrances to and inside of
buildings, shall not be less than 8 feet from the center line of the
track.
(h) Switchboxes,
switch-operating mechanisms, and accessories necessary for the control and
operation of signals and interlockers projecting 4 inches or less above the top
of the rail shall not be less than 3 feet from the center line of the
track.
(i) The center spindle of
signal and switch stands 3 feet or less above the top of the rail and located
between tracks, if not practicable to provide the clearances otherwise
prescribed in this section, shall not be less than 6 feet from the center line
of the track.
(j) Through bridges
supporting track affected, tunnels, water columns, and oil columns should not
be less than 8 feet from the center line of the track, except if special
protection is required for unusual commodities.
(k) Clearances for through bridges supporting
track affected, water barrel platforms and refuge platforms on bridges and
trestles not provided with walkways, handrails, water barrels, water columns,
oil columns, block signals, cattle guards, and stock chutes if all or portions
thereof are 4 feet or less above the top of the rail, may be decreased to the
extent defined by a line extending diagonally upward from a point level with
the top of the rail and 5 feet distant laterally from the center line of the
track to a point 4 feet above the top of the rail and 8 feet distant laterally
from the center line of the track to a point 4 feet above the top of the rail
and 8 feet distant laterally from the center line of the track; however, the
minimum clearance for handrails and water barrels on bridges with walkways
shall be 7 feet, 9 inches, and the minimum clearance for fences for cattle
guards shall be 6 feet, 9 inches.
(l) Lesser clearances, authorized in
subsection (k) providing for handrails and water barrels, do not apply to
through bridges if the work of trainmen or yardmen require them to be upon the
decks of such bridges for the purpose of coupling and uncoupling cars in the
performance of switching service on a switching lead.
(m) The side clearances specified in this
section do not apply to mail cranes during such time as arms of such mail
cranes are supporting mail sacks for delivery, if the top arm is not higher
than 10 feet, 8 inches, above the top of the rail and neither arm extends
within 6 feet, 5 inches, from the center line of the track.
(n) Icing platforms and supports shall have a
minimum side clearance of eight feet.
(o) Operations over portions of track
adjacent to icing platforms previously constructed with a side clearance of
less than eight feet shall be restricted, except in emergencies, to the
movement or switching of trains containing refrigerator cars to be iced, and
necessary use of such tracks for the unloading of supplies required for the
operation of an icing dock.
(p) The
side clearances specified in this section do not apply to intertrack fences
located on the center line between tracks.
(q) The clearances provided in this section
do not apply to enginehouses, enginehouse facilities, tipples, or facilities
used for servicing cars or for loading or unloading of bulk commodities, if
such compliance is not reasonably practicable.
(r) The side clearances specified in this
section do not apply to car retarders, derails, switch point protectors,
guardrails, and similar appurtenances projecting 3 inches or less above the top
of the rail.
(s) All minimum side
clearances prescribed in this section are for tangent tracks. Structures
adjacent to curve tracks shall have additional minimum side clearance
compensating for curvature.