52 Pa. Code § 59.20 - Meter-testing equipment
(a)
General testing equipment. Each public utility furnishing
metered gas service shall own and maintain the equipment and facilities
necessary for accurately testing the various types and sizes of meters used by
such utility for the measurement of gas, unless arrangements are made to have
the testing done in a shop or laboratory containing equipment and operated in a
manner acceptable to the Commission. The accuracy of provers and method of
operation will be checked periodically by the Commission. Alterations,
accidents, or repairs to stationary meter-proving equipment, which might affect
the accuracy of the equipment or the method of operating it, shall be promptly
reported in writing to the Commission. The accuracy of testing instruments and
equipment used as utility standards, such as dead-weight testers and precision
type pressure gauges, which are used in the testing or calibration of meters or
associated metering equipment will be checked periodically by the
Commission.
(b)
Equipment
for testing small capacity meters. Each public utility shall own and
maintain, except as provided in subsection (a), one meter prover of approved
type and of a capacity adequate for the testing of small capacity meters. Each
meter prover shall be supplied with accessories needed for accurate meter
testing, be located in a room suitable for meter testing, and be protected from
drafts and excessive changes of temperature. If the proving system includes
automatic testing equipment or any mechanical devices to provide "read-out"
capability-the entire meter proving system, including the basic prover, shall
be maintained in good condition and correct adjustment so that it will be
capable of determining the accuracy of any service meter to within
0.5%.
(c)
Equipment for
testing large capacity meters. Each public utility furnishing
metered-gas service through orifice, turbine, or large displacement
meters-except as provided in subsection (a)-shall have available and maintain
in proper adjustment test equipment suitable for determining the accuracy of
any orifice or large displacement meter used by the utility to within 0.5%. If
the public utility uses a transfer prover standard for testing large capacity
meters, the accuracy of the transfer prover and the method of operating will be
checked periodically by the Commission in conjunction with all prover
tests.
Notes
The provisions of this § 59.20 issued under Public Utility Code, 66 Pa.C.S. § § 501, 1301, 1304, 1501, 1502 and 1507.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.