70 Pa. Code § 6.6 - Newly-installed or repaired commercial weighing and measuring devices
(a)
Inspection required. A newly-installed or repaired commercial
weighing or measuring device, other than a UPC scanning system or PLU device,
may not be used in commerce unless it has been inspected and sealed in
accordance with the act and this part, or unless use in commerce occurs during
a period of conditional short-term use as described in subsection
(d).
(b)
Responsibilities
of installer or repairer. A registrant under this chapter shall
promptly notify the Department of a commercial weighing or measuring device it
installs or repairs. Although the initial notification may be made by
telephone, written notice shall be mailed, faxed or delivered to the Department
within 48 hours of the installation or repair. The written notice shall provide
the following with respect to the device:
(1)
The location of the newly-installed or repaired device, the date of the
installation or repair and a statement of whether the device is a
newly-installed device or a repaired device.
(2) The manufacturer's name or brand
name.
(3) The model number listed
on the device.
(4) The capacity of
the device, if applicable.
(5) The
serial number of the device.
(6)
The category or type of weighing or measuring device to which the
newly-installed or repaired device belongs.
(7) The name and telephone number of a
contact person through which the Department, a county sealer or a city sealer
may arrange an inspection of the device.
(c)
Responsibilities of
inspector.
(1)
State
inspectors. If the Department has not delegated inspection
responsibility to a county sealer or city sealer, it will inspect the
newly-installed or repaired weighing or measuring device at the earliest date
practicable, but within 15 days of the installation or repair, and affix a seal
(as required) if the device meets the requirements of the act and this
part.
(2)
County sealers
and city sealers. If the Department has delegated this inspection
responsibility to a county sealer or city sealer, it will promptly notify the
sealer of the installation or repair and the sealer shall inspect the
newly-installed or repaired weighing or measuring device at the earliest date
practicable, but within 15 days of the installation or repair, and affix a seal
(as required) if the device meets the requirements of the act and this
part.
(d)
Conditional short-term use. If the installer has fulfilled the
responsibilities described in subsection (b), an uninspected, newly-installed
or repaired commercial weighing or measuring device may be used in commerce for
no more than 15 days from the date of installation or repair. If, for any
reason, the inspection referenced in subsection (c) is not accomplished during
this 15-day period of conditional short-term use, the device will be removed
from commercial use until the inspection is completed and the Department is
notified of the completed inspection.