16 Tex. Admin. Code § 4.282 - [Effective until 7/1/2025] Minimum Design and Construction Information
(a) A permit application for a stationary
commercial fluid recycling facility shall include the layout and design of the
facility by including a plat drawn to scale with north arrow to top of the map
showing the location and information on the design and size of all receiving,
processing, and storage areas and all equipment, tanks, silos, monitor wells,
dikes, fences, and access roads.
(b) A permit application for a commercial
fluid recycling facility also shall include:
(1) a description of the type and thickness
of liners (e.g., fiberglass, steel concrete), if any, for all tanks, silos,
pits, and storage areas/cells;
(2)
for storage areas where tanks and/or liners are not used, credible engineering
and/or geologic information demonstrating that tanks or liners are not
necessary for the protection of surface and subsurface water;
(3) a map view and two perpendicular
cross-sectional views of pits and/or storage areas/cells to be constructed,
showing the bottom, sides, and dikes, showing the dimensions of each;
(4) a plan to control and manage storm water
runoff and to retain incoming wastes during wet weather, including the location
and dimensions of dikes and/or storage basins that would collect storm water
from the facility during a 25-year, 24-hour maximum rainfall event, and all
calculations made to determine the required capacity and design; and
(5) a plan for the installation of monitoring
wells at the facility.