(a) The
requirements of this subchapter apply in addition to the requirements of §
3.46 of this title (relating to
Fluid Injection into Productive Reservoirs) and any permit conditions to which
the Commission has subjected the injection wells.
(b) The operator must use a master meter or a
series of master meters to meter the total volume of anthropogenic
CO2 injected into the enhanced recovery facility. The
operator must use an individual well meter to meter the volume of anthropogenic
CO2 injected into each injection well. When
anthropogenic CO2 is commingled outside the enhanced
recovery facility with other CO2, the operator shall
report the total volume of anthropogenic CO2 in the
mixed stream and may account for the anthropogenic CO2
for the master meter and injected well volumes on an allocated basis.
(c) The operator must install and use
continuous recording devices to monitor the injection pressure and the rate,
volume, and temperature of the CO2 stream. The operator
must monitor the pressure on the annulus between the tubing and the long string
casing. The operator must continuously record, continuously monitor, or control
by a preset high-low pressure sensor switch the wellhead pressure of each
injection well.
(d) The operator
must fill the annulus between the tubing and the long string casing with a
corrosion inhibiting fluid approved by the director.
(e) The operator of an injection well subject
to this subchapter must maintain and comply with the approved monitoring,
sampling, and testing plan to verify that the facility is operating as
permitted and that the injected fluids are confined to the injection zone. The
director may require additional monitoring as necessary to determine compliance
with the intent of this subchapter.
(f) An operator registered under this
subchapter must submit, as applicable, a description of any proposed well
stimulation program and a determination that well stimulation will not
compromise containment.
(g) In
addition to the requirements of §
3.14 of this title (relating to
Plugging), the operator of an enhanced recovery facility subject to this
subchapter must, prior to plugging:
(1) flush
each injection well with a buffer fluid;
(2) measure to determine bottomhole reservoir
pressure;
(3) perform final tests
to assess mechanical integrity; and
(4) ensure that the material to be used in
plugging is compatible with the CO2 stream and the
formation fluids.
(h) In
any registration for geologic storage of anthropogenic
CO2 incidental to enhanced recovery, the director shall
impose terms and conditions reasonably necessary to prevent the escape of
CO2.