26 Tex. Admin. Code § 744.3305 - How do I measure the use zone for soft contained play equipment?
(a) The use zone for entrances and exits to
the soft contained play equipment, excluding slide exits, is a minimum of five
feet from all portions of the entrance and exit which are outside of the
contained area of the equipment.
(b) The use zone in front of slide exits must
extend a minimum of five feet if the slide run-out is 36 inches or greater. If
the slide run-out is less than 36 inches, the use zone at the end of the slide
must be six feet. In addition, this use zone may not overlap with any other use
zones.
(c) Entrances and exits that
terminate inside of the soft contained play equipment are exempt from use zone
requirements.
(d) External portions
of the soft contained play equipment that contain no designated play surfaces
and serve only to enclose the equipment are exempt from use zone
requirements.
(e) The critical
height of resilient surfacing material must be equal to the highest designated
play surface outside of the contained area of the equipment or for one foot,
which ever is greater.