28 Tex. Admin. Code § 5.4625 - Inspection Reports
(a) An appointed
qualified inspector or a designated representative under the appointed
qualified inspector's supervision must prepare a written inspection report for
each inspection. Except as provided in subsection (b) of this section, all
inspection reports must include the following:
(1) the complete physical address of the
inspected property (including street, street number, city, county, and ZIP
code);
(2) the subject of the
inspection (for example, entire structure, addition, alteration, or
repair);
(3) the type of
construction inspected (for example, commercial tilt wall or residential wood
frame);
(4) information indicating
where actual inspections occurred, including, at the appointed qualified
inspector's discretion:
(A) the plan or
sketches, with inspection notes on whichever the appointed qualified inspector
chooses; and
(B) the plan or
sketches, with notes on whichever the appointed qualified inspector chooses
showing the location of photographs taken as part of the inspection;
(5) the wind zone location (Inland
I, Inland II, or Seaward) (initial inspection only);
(6) the exposure category of the structure
(initial inspection only);
(7) the
structure's mean roof height (initial inspection only);
(8) a complete description of the building
products used, including:
(A) the
manufacturer's name and product name;
(B) product testing information or product
evaluation;
(C) the manufacturer's
installation instructions, including any special instructions for high wind
areas;
(D) fastener type, length,
type of corrosion resistance, and placement; and
(E) the contractor's means and methods used
to install the product;
(9) all discrepancies between the ongoing
improvement's as-built construction and the design documents and
specifications;
(10) all
discrepancies between the building products specified and the building products
installed;
(11) legible copies of
labels of all installed components and other manufacturer information,
including shingle wrappers;
(12) a
description of any action taken to remedy any discrepancies described in
paragraphs (9) and (10) of this subsection;
(13) the status of the inspection, indicating
whether the appointed qualified inspector approved or disapproved the
structure;
(14) the date and
printed name and signature of the appointed qualified inspector or the
designated representative of the appointed qualified inspector; and
(15) the date or dates of the inspection or
inspections.
(b)
Information that is listed in subsection (a) of this section does not need to
be included in an inspection report, as long as that information is contained
in the design documents listed in §
5.4623(a) of
this title (relating to Information Required to Inspect to Design Documents).
The appointed qualified inspector will still be responsible for providing this
information to TDI if requested under §
5.4626 of this title (relating to
Substantiating Information).