37 Tex. Admin. Code § 259.236 - Detoxification Cells
A facility shall provide one or more detoxification cells for detention during the detoxification process. These cells shall include the following features and equipment.
(1)
Seating. A stationary bench or benches abutting the walls shall be provided.
Benches shall be not higher than 8" above the finished floor, not less than 2'
0" wide and shall extend the length of the cell.
(2) Plumbing. Cells shall be provided with
one or more vandal resistive flushing floor drains with outside controls, or
detention type toilet and lavatory and vandal resistive floor drains. The floor
shall be properly pitched to drains. Drinking fountains or lavatories capable
of providing drinking water shall be provided.
(3) Cell Size. The size of the cell shall be
determined by the anticipated maximum number of intoxicated inmates to be
confined at any one time. Cells shall be constructed to house from 1 to 8
inmates and shall contain not less than 40 square feet of floor space for the
first inmate and 18 square feet of floor space for each additional inmate to be
confined.
(4) Surfaces. Floor,
wall, door and ceiling material shall be durable and easily cleaned.
(5) Supervision. The cell shall be located
and constructed to facilitate supervision of the cell area and to materially
reduce noise.