37 Tex. Admin. Code § 261.139 - Detoxification Cells
Any facility that anticipates the housing of intoxicated persons should provide one or more detoxification cells for the detention of persons during the detoxification process. These cells shall include the following features and equipment.
(1)
Seating. A stationary bench or benches abutting the walls shall be provided.
Benches shall be not higher than eight inches above the finished
floor.
(2) Plumbing. Cells should
be provided with one or more vandal resistive flushing floor drains with
outside controls, or vandal resistive toilet, lavatory, and standard floor
drains. The floor shall be properly pitched to drains. Drinking fountains or
lavatories capable of providing drinking water should be provided.
(3) Cell Size. The size of the cell shall be
determined by the anticipated maximum number of intoxicated inmates to be
confined at any one time. Cells shall be constructed to house from one to 12
inmates and shall contain not less than 40 square feet of floor space for one
inmate and 18 square feet of floor space for each additional inmate to be
confined.
(4) Surfaces. Floor, wall
and ceiling material shall be durable and easily cleaned.
(5) Supervision. The cell shall be located
and constructed to facilitate supervision of the cell area and to materially
reduce noise.