Utah Admin. Code R307-206-5 - Visible Emission Evaluation Techniques
(1) Visible emissions shall be measured using
EPA Method 9. Visible emissions from intermittent sources shall use procedures
similar to Method 9, but the requirement for observations to be made at 15
second intervals over a six-minute period shall not apply.
(2) Visible emissions from unconfined
blasting shall be measured at the densest point of the emission after a major
portion of the spent abrasive has fallen out, at a point not less than five
feet nor more than twenty-five feet from the impact surface from any single
abrasive blasting nozzle.
(3) An
unconfined blasting operation that uses multiple nozzles shall be considered a
single source unless it can be demonstrated by the owner or operator that each
nozzle, measured separately, meets the emission and performance standards
provided in
R307-206-2 through 4.
(4) Visible emissions from
confined blasting shall be measured at the densest point after the air
pollutant leaves the enclosure.