Utah Admin. Code R307-306-5 - Visible Emission Evaluation Techniques
(1) Visible emissions shall be measured using
EPA Method 9. Visible emissions from intermittent sources shall use procedures
similar to Method 9, but the requirement for observations to be made at 15
second intervals over a six minute period shall not apply.
(2) Visible emissions from unconfined
blasting shall be measured at the densest point of the emission after a major
portion of the spent abrasive has fallen out at a point not less than five feet
nor more than twenty-five feet from the impact surface from any single abrasive
blasting nozzle.
(3) An unconfined
blasting operation that uses multiple nozzles shall be considered a single
source unless it can be demonstrated by the owner or operator that each nozzle,
measured separately, meets the visible emission standards in
R307-306-4.
(4) Emissions from confined
blasting shall be measured at the densest point after the air pollutant leaves
the enclosure.