Utah Admin. Code R307-342-6 - Application Equipment
(1) An operator
shall only use the following equipment to apply adhesives and sealants:
(a) Electrostatic application;
(b) Flow coater;
(c) Roll coater;
(d) Dip coater;
(e) Hand application method;
(f) Airless spray and air-assisted airless
spray;
(g) High volume, low
pressure spray equipment operated in accordance with the manufacturers
specifications; or
(h) Other
methods having a minimum 65% transfer efficiency.
(2) Removal of an adhesive, sealant, adhesive
primer or sealant primer from the parts of spray application equipment shall be
performed as follows:
(a) In an enclosed
cleaning system;
(b) Using a
solvent (excluding water and solvents exempt from the definition of volatile
organic compounds found in
R307-101-2) with a
VOC content less than or equal to 70 grams of VOC per liter of material; or
(c) Parts containing dried
adhesive may be soaked in a solvent if the composite vapor pressure of the
solvent, excluding water and exempt compounds, is less than or equal to 9.5 mm
Hg at 20 degrees Celsius and the parts and solvent are in a closed container
that remains closed except when adding parts to or removing parts from the
container.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.