(1) Control
techniques and work practices shall be implemented at all times to reduce VOC
emissions. Control techniques and work practices shall include:
(a) Storing all VOC-containing coatings,
thinners, and coating-related waste materials in closed containers, containers
with activated carbon or other control method approved by the EPA
Administrator;
(b) Ensuring that
mixing and storage containers used for VOC-containing coatings, thinners, and
coating-related waste material are kept closed at all times except when
depositing or removing these materials, unless a container has activated carbon
or other control method approved by the EPA Administrator;
(c) Minimizing spills of VOC-containing
coatings, thinners, and coating-related waste materials; and
(d) Conveying VOC-containing coatings,
thinners, and coating-related waste materials from one location to another in
closed containers, containers with activated carbon or other control method
approved by the EPA Administrator, or pipes; and
(e) Minimizing VOC emission from cleaning of
application, storage, mixing, and conveying equipment by ensuring that
equipment cleaning is performed without atomizing the cleaning solvent and all
spent solvent is captured in closed containers.
(2) Solvent cleaning operations shall be
performed using cleaning materials having a VOC composite vapor pressure no
greater than 1 mm Hg at 20 degrees Celsius, unless an add-on control device is
used as specified in
R307-350-8.