Utah Admin. Code R307-508-3 - VOC Control Device Requirements
(1) A VOC
control device required by Rule R307-506 or R307-507 must have a control
efficiency of 95% or greater
(a) The VOC
control device shall operate with no visible emissions.
(b) The VOC control device must comply with
Rule R307-503.
(2) A
well site shall demonstrate compliance by meeting the performance test methods
and procedures specified in
40
CFR 60.5413a.
(3) VOC control devices and all associated
equipment shall be inspected monthly by audio, visual, or olfactory (AVO) means
to ensure the integrity of the equipment is maintained and is operational. If
equipment is not operational, corrective action shall be taken within 15 days
of discovery.