Utah Admin. Code R313-15-503 - Location of Individual Monitoring Devices
Each licensee or registrant shall ensure that individuals who are required to monitor occupational doses in accordance with Subsection R313-15-502(1) wear individual monitoring devices as follows:
(1) An individual monitoring device used for
monitoring the dose to the whole body shall be worn at the unshielded location
of the whole body likely to receive the highest exposure. When a protective
apron is worn, the location of the individual monitoring device is typically at
the neck (collar).
(2) An
individual monitoring device used for monitoring the dose to an embryo/fetus of
a declared pregnant woman, pursuant to Subsection
R313-15-208(1),
shall be located at the waist under any protective apron being worn by the
woman.
(3) An individual monitoring
device used for monitoring the lens dose equivalent, to demonstrate compliance
with Subsection
R313-15-201(1)(b)(i),
shall be located at the neck (collar), outside any protective apron being worn
by the monitored individual, or at an unshielded location closer to the
eye.
(4) An individual monitoring
device used for monitoring the dose to the extremities, to demonstrate
compliance with Subsection
R313-15-201(1)(b)(ii),
shall be worn on the extremity likely to receive the highest exposure. Each
individual monitoring device shall be oriented to measure the highest dose to
the extremity being monitored.