Utah Admin. Code R315-264-1059 - Standards: Delay of Repair
(a) Delay of
repair of equipment for which leaks have been detected will be allowed if the
repair is technically infeasible without a hazardous waste management unit
shutdown. In such a case, repair of this equipment shall occur before the end
of the next hazardous waste management unit shutdown.
(b) Delay of repair of equipment for which
leaks have been detected will be allowed for equipment that is isolated from
the hazardous waste management unit and that does not continue to contain or
contact hazardous waste with organic concentrations at least 10 percent by
weight.
(c) Delay of repair for
valves will be allowed if:
(1) The owner or
operator determines that emissions of purged material resulting from immediate
repair are greater than the emissions likely to result from delay of repair.
(2) When repair procedures are
effected, the purged material is collected and destroyed or recovered in a
control device complying with Section
R315-264-1060.
(d) Delay of repair for
pumps will be allowed if:
(1) Repair requires
the use of a dual mechanical seal system that includes a barrier fluid system.
(2) Repair is completed as soon as
practicable, but not later than 6 months after the leak was detected.
(e) Delay of repair
beyond a hazardous waste management unit shutdown will be allowed for a valve
if valve assembly replacement is necessary during the hazardous waste
management unit shutdown, valve assembly supplies have been depleted, and valve
assembly supplies had been sufficiently stocked before the supplies were
depleted. Delay of repair beyond the next hazardous waste management unit
shutdown will not be allowed unless the next hazardous waste management unit
shutdown occurs sooner than 6 months after the first hazardous waste management
unit shutdown.