Utah Admin. Code R315-264-304 - Response Actions
(a) The owner or
operator of landfill units subject to Subsections
R315-264-301(c)
or (d) shall have an approved response action
plan before receipt of waste. The response action plan shall set forth the
actions to be taken if the action leakage rate has been exceeded. At a minimum,
the response action plan shall describe the actions specified in Subsection
R315-264-304(b).
(b) If the flow
rate into the leak detection system exceeds the action leakage rate for any
sump, the owner or operator shall:
(1) Notify
the Director in writing of the exceedance within 7 days of the determination;
(2) Submit a preliminary written
assessment to the Director within 14 days of the determination, as to the
amount of liquids, likely sources of liquids, possible location, size, and
cause of any leaks, and short-term actions taken and planned;
(3) Determine to the extent practicable the
location, size, and cause of any leak;
(4) Determine whether waste receipt should
cease or be curtailed, whether any waste should be removed from the unit for
inspection, repairs, or controls, and whether or not the unit should be closed;
(5) Determine any other short-term
and longer-term actions to be taken to mitigate or stop any leaks; and
(6) Within 30 days after the
notification that the action leakage rate has been exceeded, submit to the
Director the results of the analyses specified in Subsections
R315-264-304(b)(3), (4), and (5), the results of actions taken, and actions
planned. Monthly thereafter, as long as the flow rate in the leak detection
system exceeds the action leakage rate, the owner or operator shall submit to
the Director a report summarizing the results of any remedial actions taken and
actions planned.
(c) To
make the leak and/or remediation determinations in Subsections
R315-264-304(b)(3), (4), and (5), the owner or operator shall:
(1)
(i)
Assess the source of liquids and amounts of liquids by source,
(ii) Conduct a fingerprint, hazardous
constituent, or other analyses of the liquids in the leak detection system to
identify the source of liquids and possible location of any leaks, and the
hazard and mobility of the liquid; and
(iii) Assess the seriousness of any leaks in
terms of potential for escaping into the environment; or
(2) Document why such assessments are not
needed.